APPENDIX Troubleshooting
You press Power switch, but there is no reaction.
- The power switch on the rear panel is switched off.
You cannot turn the power off.
- Press and hold the Power switch for 3 seconds, then release to power off
No sound through the FireworX.
- You are using Analog input, but the input selector in I/O Setup, Audio menu is set to AES/EBU, S/PDIF or ADAT or Insert is different
from “None”
The sound is phasing with your direct signal.
- You are running the FireworX in a parallel setup, but the Mix function in I/O Setup, Signal menu is set to “Wet”.
- The Insert loop is causing phase cancellation (See Insert loop for further explanation).
Right input meter is not showing any signal.
- You selected “L” in the source parameter in I/O Setup, signal page.
Effects only in the Left Output
- You are only using Left input, but the Input selector in I/O Setup is set to Stereo.
Your Expression pedal does not work properly
- Be sure the FireworX is set to the correct pedal type and the pedal is calibrated correctly in the Utility menu.