10.1 Installation Details
Connecting pipe length
Model
Pipe size(Inch)
Liquid
Gas
FMA-18I2HD/DVO
1/4
3/8
FMA-27I3HD/DVO
1/4
3/8
Mode
Standard length: m
Refrigerant piping
Max. length: m
A
Additional refrigerant B
Calculation: ×g=Bg/m(A-5m)
FMA-18I2HD/DVO
5.0
25
15g/m
FMA-27I3HD/DVO
5.0
25
15g/m
Connecting cables
The power cord should be selected according to the following specifications sheet.
Appliance Amps
Wire Size
5
AWG21/0.75 mm2
10
AWG18/1.0 mm2
13
AWG15 /1. 5 mm2
18
AWG14/1.6 mm2
25
AWG12/2.0 mm2
30
AWG10/2.5 mm2