Air Conditioner Service Manual 
 
32 
5).The cable connecting the outdoor and indoor 
units must be suitable for outdoor use. 
6).The plug must be accessible also after the 
appliance has been installed so that it can be 
pulled out if necessary. 
7).An efficient earth connection must be 
ensured. 
8).If the power cable is damaged, it must be 
replaced by an authorized Service Centre. 
 
 
 
 
 
 
 
 
 
 
 
10.2.4   Refrigerant piping connection 
The piping can be run in the 3 directions indicated 
by numbers in the picture. When the piping is run 
in direction 1 or 3, cut a notch along the groove on 
the side of the indoor unit with a cutter. 
Run the piping in the direction of the wall hole and 
bind the copper pipes, the drain pipe and the 
power cables together with the tape with the drain 
pipe at the bottom, so that water can flow freely. 
 
 
 
 
 
 
 
 
 
10.2.5 Connecting the pipes. 
  Do not remove the cap from the pipe until 
connecting it, to avoid dampness or dirt 
from  entering. 
   If the pipe is bent or pulled too often, it will 
become stiff. Do not bend the pipe more 
than  three times at one point. 
   When extending the rolled pipe, straighten 
the  pipe by unwinding it gently as shown in 
the  picture. 
 
 
 
 
 
10.2.6 Connections to the indoor unit 
1).Remove the indoor unit pipe cap (check that 
there is no debris inside). 
2).Insert the fare nut and create a flange at the 
extreme end of the connection pipe. 
3).Tighten the connections by using two wrenches 
working in opposite directions. 
 
 
 
 
 
 
 
 
10.2.7 Indoor unit condensed water drainage 
The indoor unit condensed water drainage is 
fundamental for the success of the installation. 
1).Place the drain hose below the piping, taking 
care not to create siphons. 
2).The drain hose must slant downwards to aid 
drainage. 
3).Do not bend the drain hose or leave it protruding 
or twisted and do not put the end of it in water. 
If an extension is connected to the drain hose, 
ensure that it is lagged when it passes into the 
indoor unit. 
4).If the piping is installed to the right, the pipes, 
power cable and drain hose must be lagged and 
secured onto the rear of the unit with a pipe 
connection. 
 Insert the pipe connection into the relative slot. 
 Press to join the pipe connection to the base. 
 
 
 
 
 
 
Front panel
Terminal block cover
 
Wiring diagram
3
2
1
Shape the connection pipe
NO
YES
Extending the  rolled pipe