the compressor will run at very low frequency. In general, unit will change its running frequency 
according toδt to make room temperature closing to set temperature. 
(2)  Outdoor temperature affects running frequency of the compressor 
Outdoor temperature affect compressor’s running frequency. Difference inlet temperature of
 
outdoor unit is adapted by difference compressor running frequency. While outdoor temperature is 
about 30℃, the compressor will run in high frequency. 
If unit run in “cooling” mode and outdoor temperature is less than -2℃,the controller will shut down 
compressor and show error code, while the ambient temperature is over 1℃, the compressor will run 
automatically.
(3)  Auto fan control in cooling mode 
In cooling mode (include cooling in “feel” mode), fan speed is determined by 
δ
t, as the following 
diagram: 
4.“DRY” Mode Operation 
(1)
 The system for DRY operation used the same refrigerant circle as the cooling one. 
(2) When the system operates in DRY mode, at first it operates in cooling mode, the set 
temperature (ST) is “RT-2℃”. After that, t he system will operate in cooling mode with lowest 
fan speed for  30  minutes and then change to middle speed for 30seconds as a cycle. During 
the course of this operation, you can’t use remote controller to adjust the fan speed but you can 
control the vane direction. 
(3) In the dry mode, when RT≤12℃, the compressor will stop and operates again at RT≥14℃. 
5. “HEATING” Mode Operation (available for Heat Pump only)
(1) Frequency control 
Same as the frequency control in cooing mode, the running frequency of compressor is 
controlled by controller. Unit change its running frequency according to 
δ
t to make the room 
temperature closing to the set temperature. 
(2)  Indoor fan motor control 
1) Cold Air Prevention C
ontrol
z  The function is intended to prevent cold air from being discharged when heating mode 
selected or while in defrosting. 
z  The indoor fan speed will be controlled as following. 
z  In heating operation, if air conditioner turn off, the indoor fan motor will run most for 30 
RT‐ST
℃
3.5
3.0
1.5
1.0
δt come down
 
δt come up
 
High fan
 
Min fan
 
Low fan
 
Breeze  
Temperature up 
Temperature down 
Setting  
Low fan 
Stop  
37
℃ 
33
℃ 
25
℃ 
34
℃
28℃
22℃