TCL Air Conditioner Service Manual
9. Installation manual
9.1 Installation Details
Connecting pipe length
Model
Pipe size(Inch)
Liquid Gas
TAC‐09CHSD/XPI
1/4 3/8
TAC‐12CHSD/XPI
1/4 3/8
TAC‐09CHSD/YA11I
1/4 3/8
TAC‐12CHSD/YA11I
1/4 3/8
Mode Standard length: m
Refrigerant piping
Max. length: m
Additional refrigerant
Calculation: ×g=20g/m(A-5m)
TAC‐09CHSD/XPI
3.0 15 20g/m
TAC‐12CHSD/XPI
3.5 15 20g/m
TAC‐09CHSD/YA11I
3.0 15 20g/m
TAC‐12CHSD/YA11I
3.5 15 20g/m
Connecting cables
The power cord should be selected according to the following specifications sheet.
A
ppliance Amps Wire Size
5
A
WG21/0.75 mm
2
10
A
WG18
/
1.0 mm
2
13
A
WG15 /1. 5 mm
2
18
A
WG14
/
1.6 mm
2
25
A
WG12
/
2.0 mm
2
30
A
WG10
/
2.5 mm
2
Outdoor unit
Indoor unit
Pi pe length is
15 meters Max.