MODEL
OUTPUT VOLTAGE (*1)
OUTPUT CURRENT (*2)
RATED OUTPUT POWER
LOAD REGULATION
LINE REGULATION
RMS RIPPLE
RIPPLE
RECOVERY TIME (*4)
TEMPERATURE COEFFICIENT
TEMPERATURE DRIFT
(5Hz-1MHz Bandwid
th)
(pk to pk 20MHz Bandwid
th)
LOAD REGULATION
LINE REGULATION
RMS RIPPLE
TEMPERATURE COEFFICIENT
TEMPERATURE DRIFT
(5Hz-1MHz Bandwid
th)
INPUT VOLTAGE (*7)
INPUT CURRENT (*6)
INPUT CURRENT HARMONICS
POWER FACTOR (TYP)
EFFICIENCY (*6)
INRUSH CURRENT
100/200V
VOLTAGE
CURRENT
STATUS
UP PROGRAMMING RESPONSE TIME
FULL LOAD
NO LOAD
RESOLUTION
ACCURACY
RESOLUTION
ACCURACY
VOLTAGE
CURRENT
CONSTANT
VOLTAGE
CONSTANT
CURRENT
DOWN
PROGRAMMING
RESPONSE TIME
PROGRAM-
MING
(*3)
DISPLAY
OVERVOLTAGE PROTECTION
(*5)
HOLD UP TIME
OUTPUT PROTECTIONS
INPUT
ZUP60-14
0 ~ 14
20
11.2 / 5.4
80 / 84
0 ~ 24
30
11.2 / 5.4
80 / 84
0 ~ 40
60
11.2 / 5.4
79 / 82
0 ~ 80
100
11.2 / 5.4
77 / 81
0 ~ 132
792
800
800
864
840
200
11.2 / 5.4
74 / 77
30
0.005% +2mV from no load to full load, const
ant input voltage
0.005% +1mV from 85-132V
AC or 170-265VAC, constant load
5
80
30ppm/ °C from rated volt
age following 30-minute warm-up
0.01% +2mV change in output over 8-hour interval under const
ant line, load and ambient
temperature following 30-minute warm-up
50
ZUP36-24
ZUP20-40
ZUP10-80
ZUP6-132
250
0-7.5
1
100
8
70
5
350
0-13
0.5
90
8
60
5
400
0-24
0.2
0.07% + 10mA for load voltage change equal to unit volt
age rating , constant input voltage.
0.01% +5mA from 85-132VAC or 170-265VAC, constant load
20mS at 100V/200VAC, rated output volt
age and output current
100ppm/ C from rated current following 30 minute warm-up
O
0.05% +10mA change in output over 8-hour interval under const
ant line, load and ambient
temperature following 30 minute warm-up
3 digits (6V, 20V, 36V, 60V) 3.5 digits (10V) accuracy: 0.2% +/- 2 digit
s
3.5 digits (132A), all others 3 digit
s accuracy: 0.5% +/- 3 digit
s
CV/CC, Alarm, Fold, Local/Remote, ON/OFF
Over Voltage, Over Temperature, Foldback
85 ~ 265VAC Continuous, 47 ~ 63Hz
Complies with EN61000-3-2, Class
A
0.99 at 100/200VAC, 100% Load
500
0-40
0.2
750
70
0-66
0.2
0 ~ 6
0 ~ 10
0 ~ 20
0 ~ 36 0 ~ 60
2.1 SPECIFICATIONS: 800W Series
Better than 0.028% of rated output volt
age
0.4% + 40mA
Better than 0.03% of rated output current
50mS (From zero volt
s to full scale, resistive load, current setting at max.)
0.02% + 5mV 0.02% + 8mV 0.02% + 12mV 0.02% + 26mV 0.02% + 35mV