4.5 MINIMUM SAFETY DISTANCES
A 50 cm from rear wall
B 40 cm from lateral wall
C 100cm from front side
Flammable materials and
furniture should not be
placed at a distance of 100
cm in the radiation area (C)
of the flame monitoring
cover.
While installing the stove, the fire regulations and chimney’s instructions must be complied.
For any related questions please ask the chimney provider. Minimum distances to be
observed in flammable or heat-sensitive materials (eg furniture, wallpaper, wood panels)
(see diagram above) are:
This distance can be reduced to 40 cm when the protection panel is placed between the
stove and the materials that are likely to burn.
Minimum distances for flammable materials and furniture are indicated on the product
label and must not be exceeded. If the floor where the stove is to be installed is flammable
or heat-sensitive, you should place the product on the ground protection plate (eg marble
or glass base).