EasyManua.ls Logo

Techfrost E Series - 12 ERRORS; 12.1 Errors

Techfrost E Series
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
49
www.techfrost.com
ENGLISH
12 ERRORS
12.1 Errors
The following chart illustrates the error code meaning.
Code Meaning
Pr1
Cell probe error.
Remedy:
-please check the parameter P0 value
-please check the cell probe intact state
-please check the device-probe connection
-please check the cell temperature
Main consequences:
-if the error occurs during the state “stand-by”, it won’t be possible to select
or start any cycle
-if the error occurs during the blast chilling or the blast freezing, the cycle
will be stopped
-if the error occurs during the conservation, the compressor activity will de-
pend on the parameters C4 and C5 or C9
-the defrosting won’t never be started
-the door restors won’t never be switched on
-the minimum temperature alarm (code “AL”) won’t never be activated
-the maximum temperature alarm (code “AH”) won’t never be activated
Pr2
Core probe error.
Remedy:
-the same errors of the cell probe (code “Pr1”) but relating to the core pro-
be.
Main consequences:
-if the error occurs during the state “stand-by”, the temperature fonction-
ning cycle will be activated by time
-if the error occurs during the temperature blast chilling, the cycle will stop
within the time set by the parameter r1
-if the error occurs during the temperature blast freezing , the cycle will
stop within the time set by the parameter r2
-if the error occurs during the core probe warm up, the cycle will be stop-
ped.
Pr3
Evaporator probe error.
Remedy:
-the same cell probe errors (code “Pr1”) but referred to the evaporator pro-
be.
Main consequences:
-if the parameter P4 is set to 1, the defrosting cycle will be completed wi-
thin the time set by the parameter d3
-if the parameter F0 is set to 1, the parameter F16 won’t have any eect
-if the parameter F4 is set to 1, the device will work as the parameter would
be set to 2

Table of Contents