ground connector on the Inverter and a clean electrical grounding point on the
vehicle. This will minimize possible electrical noise interference when using
TVs or radios.
Note: Sparking is normal for first connection.
Operation
Before using the power inverter determine your equipment’s total watts!
Do not connect more watt than the Output Power (maximum continuous
watt) of the device ( see technical specifications).
Determine Total Wattage Required, Watt ratings are usually listed in
equipment manuals or on nameplates. If your equipment is rated in Amp,
multiply that number times AC utility voltage to determine watts.
(mathematic example: a drill requires 1.5A 1.5A x 230Volt = 345Watt. No
problem to use the drill.)
Remember the vehicle‘s battery will be discharged when the vehicle is not
running.
To Determine DC Battery Amps Required, divide the total wattage
required (from above) by the nominal battery voltage to determine the DC
amps required. 345Watt / 12V = 28.75A DC
To Estimate Battery Amp-Hours Required Multiply the DC amps required
(from above) by the number of hours you estimate you will operate your
equipment exclusively from battery power before you have to recharge your
batteries with utility- or generator-supplied AC power. Compensate for
inefficiency by multiplying this number by 1.2. This will give you a rough
estimate of how many amp-hours of battery power (from one or several
batteries) you should connect to your Inverter/Charger.
28.75A DC x 0.5h runtime x 1.2 inefficiency rating = 17.25 amp-hours
To Estimate Battery Recharge Required, Given Your Application You
must allow your batteries to recharge long enough to replace the charge lost
during inverter operation or else you will eventually run down your batteries.
To estimate the minimum amount of time you need to recharge your batteries
given your application, divide your required battery amp-hours (from above) by
your Inverter/Chargers rated charging amps (depending on the ON/OFF
settings).
17.25 amp-hours / 40A inverter/charger rating = 0.43h recharge