SL-PG200A
Measuring
Instruments
*
Playability
test
disc
(SZZP1054C).
*
Dual-beam
oscilloscope
with
bandwidth
of
30MHz
or
*
Normal
disc.
better
(with
EXT
trigger
and
1:
1
probe).
(1)
LASER
POWER
ADJUSTMENT
1.
Connect
the
oscilloscope’s
CH1
probe
across
(+)
and
(—)
of
R3501
(Resistor)
on
the
servo
P.C.B.
2.
Switch
the
player
power
ON,
and
play
track
No.
1
on
the
test
disc
(SZZP1054C).
3.
Adjust
VR3520
so
that
the
voltage
is
—50+2mV.
Oscilloscope
setting:
[
r
VOLT
.....
cee
20mV
SWEEP............
0.2msec.
INPUT..........0..
DC
4
(2)
FOCUS
OFFSET
ADJUSTMENT
1.
Connect
the
oscilloscope’s
CH1
probe
across
R3562
(Resistor)
(+)
and
Jumper
(—)
on
the
servo
P.C.B.
2.
Switch
the
player
power
ON,
and
play
track
No.
1
on
the
test
disc
(SZZP1054C).
3.
Adjust
VR3569
until
the
signal
amplitude
become
in
the
center
of
400mV.
Oscilloscope
setting:
VOLT
.......
eee
200mV
SWEEP............
5msec
INPUT.............
DC
(3)
CHECK
OF
PLAY
OPERATION
AFTER
ADJUSTMENT
*
Checking
Skip
Search
*
Playability
check
by
test
disc
1.
Play
an
ordinary
musical
program
disc.
1.
Play
the
0.7mm
black
dot
and
the
0.7mm
wedge
on
2.
Press
the
skip
button
to
check
for
normal
skip
the
defect
test
disc
(SZZP1054C)
and
verify
that
no
search
operation
(in
both
the
forward
and
reverse
sound
skip
or
noise
occurs.
directions).
*
Checking
Manual
Search
1.
Play
an
ordinary
musical
program
disc.
2.
Press
the
manual
search
button
to
check
for
smooth
manual
search
operations
at
either
low
or
high
speed
(in
both
the
forward
and
reverse
directions).