3.1 Power Supply to Main Circuit
TOP PREVIOUS NEXT
1. Apply 10 V AC power to the section between the point TP1 and the point TP2 . Shown in
Fig.1
2. Connect the DC+12 V to+15 V (more than 0.1 A) to the point TP5 , and the GND terminal to
the point TP4 using the DC power supply. Shown in Fig.1
3. Connect the DC -12 V to -15 V (more than 0.1 A) to the point TP3 , and the GND terminal to
the point TP4 using the DC power supply. Shown in Fig.1
•@