EasyManua.ls Logo

Technika TGC6IND-5 - Technical Specification

Technika TGC6IND-5
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Failure Display and Inspection
If an abnormality occurs, the induction hob will enter a protective state
automatically and display corresponding protective codes:
Problem Possible causes What to do
E4/E5 Temperature sensor failure Please contact the Technika service
department.
E7/E8
Temperature sensor of the
IGBT failure.
Please contact the Technika service
department.
E2/E3
Abnormal supply voltage
Please inspect whether power supply
is normal. Power the hob on after the
power supply is back to normal.
E6/E9 Bad induction hob heat
radiation
Please restart after the induction
hob cools down.
WARNING: For you own safety, please do not disassemble the unit by yourself.
Any repairs must be carried out by a suitably qualified technician.
Technical Specification
Induction Hob
TGC6IND-5
Cooking Zones 4 Zones
Supply Voltage 220-240V~ 50 Hz or 60Hz
Installed Electric Power 7200W
Product Size D×W×H(mm) 590×520×58
Building-in Dimensions A×B (mm) 565×495
Induction Hob TGC9IND-5
Cooking Zones 5 Zones
Supply Voltage 220-240V~ 50 Hz or 60Hz
Installed Electric Power 10800W
Product Size D×W×H(mm) 900×520×58
Building-in Dimensions A×B (mm) 860×495
Weight and Dimensions are approximate. Because we continually strive to improve our
products we may change specifications and designs without prior notice.