6 Installation
6.1 Plates
The unit is supplied with warning and attention plates as listed in the relevant table.
6.2 Dimensions
Mod. A B C D E F G H I L M X Y
SVN0050
378
250 784 307 120 27 301 525 60 430 350 306 355
SVN1060-N1075 / SVK1120-K1170
357
250 719 340 122 28 332 506 60 620 545 337 550
SVN2100-N2122-N2120 / SVK2220
390
250 809 360 122 28 332 540 60 820 745 337 750
SVN3150-N3200 / SVK3250-K3300
427
250 929 410 122 98 452 645 60 820 745 456 750
SVN4250-N4300 / SVK4450-K4500
542
250 1046
520 122 98 452 785 60 1075
1000
458 1005
6.3 Location
To obtain optimal operation of the unit act as follows:
A) Place the unit in a well ventilated room, far from heat sources.
B) Limit the number of door openings.
C) Make sure that the unit has good air supply and discharge.
D) Fit a drain line to the defrost water drain connection in the lower part of the unit.
Note: SV units are equipped with automatic evaporation of defrost water; drain is just a precaution in case
of troubles.
Inject silicone on the whole
conveyor perimeter
Condensate drain
line
D. 10
Mod. A
SVN0050
378
SVN1060-N1075 / SVK1120-K1170
357
SVN2100-N2122-N2120 / SVK2200
390
SVN3150-N3200 / SVK3250-K3300
427
SVN4250-N4300 / SVK4450-K4500
542
Solution 1
Solution 2