Low Row
D
A
Replacing the cable
- insert a thickness of approx. 10 mm (1/2 inch) under the first weight of the
weight stack;
- bring the two levers into contact with the rubber travel stops (D);
- tighten the cable and tighten the screws (A) on the other tension clamp, always
keeping the levers in contact with the rubber travel stops;
- remove the 10 mm (1/2 inch) thickness from the weight stack.
- refit the protective panel on the weight stack
WARNINGS
Carefully check the state of the cables once a month.
ALWAYS use cables supplied directly by Technogym.