EasyManua.ls Logo

Tecnam P-Mentor - Page 77

Tecnam P-Mentor
390 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
st
Edition - Rev. 0
Section 3 EMERGENCY PROCEDURES
PITOT-STATIC SYSTEM
P-Mentor Aircraft Flight Manual Page 3 - 13
3.2. Static source malfunction
The alternate source valve is located on the right side of the
central pedestal.
If static source malfunction is suspected and/or abnormal fluctuations of
indicated airspeed and/or altitude are detected in relationship with yawing:
1. Alternate static port …..…………………..........................OPEN
2. Cabin heating …................................................... OFF
Operation of the alternate static air requires that the cabin air
system be switched off in order not to affect the air pressure
measurement.

Table of Contents