1
st
Edition - Rev. 1
Section 3 – EMERGENCY PROCEDURES
POWERPLANT
P-Mentor – Aircraft Flight Manual Page 3 - 23
7.2. Engine Failure after Take-off
If engine fails immediately after becoming airborne:
Abort on the runway if possible.
In case low altitude precludes a runway stop and/or engine restart:
1. Establish a glide attitude
Find a suitable place on the ground to land safely
The landing should be planned straight ahead with only small
changes in directions not exceeding 45° to the left and 45° to the
right.
Any turn would reduce the glide performance.
2. Throttle Lever ………………………….......
4. Fuel Selector valve...………………………
5. Main Fuel Pump & Fuel Pump Switches …
6. Lane A & B Switches ….…….……………..
7. Master Switch ………………...……………
8. Parking Brake…………………..…………..
9. Aircraft Evacuation…………….…………..