EasyManua.ls Logo

TECNOMAGNETE QX Series - 9 Maintenance

TECNOMAGNETE QX Series
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
72
Instruction and maintenance manual
ENGLISH
Figure 8.7L - Flattening, contouring and boring of cast iron
parts
Figure 8.7M - 3D machining
Figure 8.7I - Flattening and contouring of cast and molded
parts
Figure 8.7N - Machining of plates with horizontal axis
9
MAINTENANCE
9.1 Premise
A correct maintenance signicantly inuences the
life cycle of the system, ensures a high performance
and fault-free operation, along with maximum func-
tional safety.
9.2 Safety precautions applicable to
maintenance
ATTENTION
Always verify that all maintenance operations are
carried out by qualied and trained personnel (para-
graph 1.7).
While performing maintenance operations, always
take into account the following:
All maintenance operations should be performed
when the system is idle and disconnected from
the power supply.
All reparations on electric systems must be per-
formed after disconnecting the system from the
power supply and enabling the emergency but-
ton. All personnel responsible for the operation,
maintenance and cleaning of the system shall
have to thoroughly follow the safety instructions
applicable to the country of installation.
Always wear safety gloves and shoes and any
other type of PPE required including overalls that
cover as much of the body as possible.
Do not wear rings, watches, chains, bracelets,
loose clothing, etc. during maintenance work.
Stand on a rubber insulating mat (if possible)
when doing maintenance work.
Avoid working on wet oors or under very damp
conditions.
Always perform maintenance operation according
to schedule.
• Always replace components with original
spare parts in order to guarantee maximum
performance.
When performing cleaning operations, avoid us-
ing grinders or abrasive, corrosive or solvent ma-
terial that could cause the removal and/or make
numbers, initials or information printed on the
system illegible.
Protect all electric and electronic equipment from
water.

Table of Contents