Tecnosystemi Blitz 510 DA - Electro-Mechanical Faults - Manifold & O-Rings; Replacing Manifold and O-Rings

Default Icon
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
fig.28b fig.28c
Remove the curve T2 (see fig.28b) Unscrew the hexagonal manifold R1 (see fig. 28c)
fig.28d fig.28e
Take the manifold out of the boiler (see fig. 28d) Replace the 2 OR 2018 (see fig. 28e)
fig.28f
NOTE
Reassemble all parts, proceeding in the reverse order (see fig. 28f) and put the sealant on the 1/8” coupling
thread. You are recommended to slightly lubricate the 2 ORs using a non-toxic fat.