17
Group 06: Automatic Program Operation
Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
06-43
Operation
Direction
Selection of
Speed-Sta
g
e 11
0: Stop
1: Forward
2: Reverse
0
06-44
Operation
Direction
Selection of
Speed-Sta
g
e 12
0: Stop
1: Forward
2: Reverse
0
06-45
Operation
Direction
Selection of
Speed-Sta
g
e 13
0: Stop
1: Forward
2: Reverse
0
06-46
Operation
Direction
Selection of
Speed-Sta
g
e 14
0: Stop
1: Forward
2: Reverse
0
06-47
Operation
Direction
Selection of
Speed-Sta
g
e 15
0: Stop
1: Forward
2: Reverse
0
* If the maximum output frequency of motor is
over 300Hz, the frequency resolution is
changed to 0.1Hz.
Group 07: Start /Stop Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
07-00
Momentary
Power Loss
and Restart
0: Disable
0
1: Enable
07-01
Fault Reset
Time
0~7200 0
07-02
Number of
Auto Restart
Attempts
0~10 0
07-03
Reset Mode
Setting
0Enable
Reset Only
when Run
Command is
Off
1Enable Reset
when Run
Command is On
or Off
0
07-04
Momentary
Power Loss
and Restart
0: Enable
Direct run on
power up
1
1: Disable
Direct run on
power up
07-05
Delay-ON
Timer
1.0~300.0 1.0
07-06
DC Injection
Braking Start
Frequency
0.0~10.0 1.5
07-07
DC Injection
Braking Level
0~100 50
Group 07: Start /Stop Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
(Current
Mode)
07-08
DC Injection
Braking Time
0.00~100.00 0.50
07-09
Stop Mode
Selection
0: Deceleration
to Stop
0
1: Coast to
Stop
2: DC Braking
Stop in All
Fields
3: Coast to
Stop with
Timer
07-10
Speed Search
Mode
Selection
0: Normal Start
1: Execute
Speed Search
Once
2: Speed
Search Start
0
07-13
Low Voltage
Detection
Level
200V:
100~300
190
400V:
250~600
380
07-15
DC Injection
Brake Mode
0: Current
Mode
1: Voltage
Mode
1
07-16
DC Injection
Braking Time
at Start
0.00~100.00 0.00
07-18
Minimum
Base block
Time
0.1~5.0 KVA
07-19
Speed
Direction
Search
Operation
Current
0~100 50
07-20
Speed Search
Operating
Current
0~100 20
07-21
Integral Time
of Speed
Searching
0.1~10.0 2.0
07-22
Delay Time of
Speed
Searching
0.0~20.0 0.2
07-23
Voltage
Recovery
Time
0.1~5.0 2.0
07-24
Direction-Det
ection Speed
Search
Selection
0: Invalid
1
1: Valid
07-25
Low Voltage
Detection
Time
0.00~1.00 0.02
07-26
Start-up Mode
Selection of
0: Start with
speed
0

Other manuals for TECO E510s Series