Appendix 1 Instructions for UL
Closed-Loop Crimp Terminal Size
Drive Model Wire Gauge mm2 (AWG) Terminal Crimp Terminal Tool Insulation
11-301(series) R/L1, S/L2, T/L3 U/T1, V/T2, W,T3 Screws Model No. Machine No. Model No.
11-301-21-2P5-30 2 (14) M3.5 R2-3.5 Nichifu NH 1/9 TIC 2
11-301-21-201-30 2 (14) M3.5 R2-3.5 Nichifu NH 1/9 TIC 2
11-301-21-202-30 3.5 (12) M4 R5.5-4 Nichifu NH 1/9 TIC 3.5
11-301-21-203-30 5.5 (10) M4 R5.5-4 Nichifu NH 1/9 TIC 5.5
11-301-43-401-30 2 (14) M3.5 R2-3.5 Nichifu NH 1/9 TIC 2
11-301-43-402-30 2 (14) M3.5 R2-3.5 Nichifu NH 1/9 TIC 2
11-301-43-403-30 2 (14) M4 R2-4 Nichifu NH 1/9 TIC 2
11-301-43-405-30 2 (14) M4 R2-4 Nichifu NH 1/9 TIC 2
11-301-43-408-30 8 (8) M4 R8-4 Nichifu NOP 60 TIC 8
11-301-43-410-30 8 (8) M4 R8-4 Nichifu NOP 60 TIC 8
11-301-43-415-30 8 (8) M4 R8-4 Nichifu NOP 60 TIC 8
11-301-43-420-30 8 (8) M4 R8-4 Nichifu NOP 60 TIC 8
11-301-43-425-30 8 (8) M4 R8-4 Nichifu NOP 60 TIC 8
11-301-43-430-30 14 (6) M6 R14-6 Nichifu NOP 60/150H TIC 14
11-301-43-440-30 38 (2) M8 R38-8 Nichifu NOP 60/150H TIC 38
11-301-43-450-30 38 (2) M8 R38-8 Nichifu NOP 60/150H TIC 38
11-301-43-460-30 38 (2) M8 R38-8 Nichifu NOP 60/150H TIC 38
11-301-43-475-30 38 (2) M8 R38-8 Nichifu NOP 60/150H TIC 38
Motor Overtemperature Protection
Motor overtemperature protection shall be provided in the end use application.
Field Wiring Terminals
All input and output field wiring terminals not located within the motor circuit shall be marked to indicate the
proper connections that are to be made to each terminal and indicate that copper conductors, rated 75°C are to be
used.
Drive Short-Circuit Rating
This drive has undergone the UL short-circuit test, which certifies that during a short circuit in the power supply the current
flow will not rise above
value. Please see electrical ratings for maximum voltage and table below for current.
The MCCB
and breaker protection and fuse ratings (refer to the preceding table) shall be equal to or greater than the short-circuit
tolerance of the
power supply being used.