EasyManua.ls Logo

TECO E510s Series - Page 26

TECO E510s Series
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
12-43
Inverter
Status
0000 0000
1: Invert er ready
1: Dur i ng runni ng
1: Dur i ng zer o speed
1: Dur i ng speed agr ee
1: Dur ing f ault det ect ion ( minor faul t )
1: Dur i ng faul t det ect ion (maj or f aul t)
Reserved
*4
12-74
Operation
Pressure
Setting
0.01 ~ 25.50 2.00
12-75
Pressure
Feedback
Value
0.01 ~ 25.50 -
12-82
Motor
Loading
Display the
Loading current
of Motor
*4
12-83
Type of
E510s
0: IP20 NFS
1: IP20 FS
2: IP66 NFS
3: IP66 FS
- *4
Group 13: Maintenance Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
13-00
Inverter
Capacity
Selection
---- - *3*4
13-01
Software
Version
0.00-9.99 - *3*4
13-02 Fault Record ---- 0 *4
13-03
Cumulative
Operation
Hours 1
0~23 - *3*4
13-04
Cumulative
Operation
Hours 2
0~65534 - *3*4
13-05
Selection of
Cumulative
Operation
Time
0: Cumulative
time in power
on
0 *1
1: Cumulative
t
ime in
o
peration
13-06
Parameters
Locked
0
: Parameters
are read-only
except 13-06
and main
frequency
2
1: Reserved
2: All
Parameters
are Writable
13-07
Parameter
Password
Function
00000~65534 00000
13-08 Restore
1: 2 wire -
Group 13: Maintenance Parameters
Code
Parameter
Name
Setting Range Default
Attribu
te
Factory
Setting
initialization
(50Hz)
(220V/380V)
2: 2 wire
initialization
(60Hz)
(220V/380V)
3: 2 wire
initialization
(50Hz)
(230V/400V)
4
: 2 wire
initialization
(60Hz)
(230V/460V)
5:2 wire
initialization
(50Hz)
(220V/415V)
6: 2 wire
initialization
(60Hz)
(230V/400V)
7: 2 wire
initialization
(50Hz)
(220V/440V)
8: 2 wire
initialization
(60Hz)
(220V/440V)
9: 2 wire
initialization
(60Hz)
(220V/380V)
10: 2 wire
initialization
(60Hz)
(220V/380V)
1112PLC
initialization
(RESET)
13-09
Fault History
Clearance
Function
0: No Clearing
Fault History
1: Clear Fault
History
0
13-10 Situation 0~9999
13-21
Last Time
Fault History
Exhibit last time
fault history
-
13-22
Previous Two
Fault History
Exhibit previous
two fault history
-
13-23
Previous
Three Fault
History
Exhibit previous
three fault
history
-
13-24
Previous Four
Fault History
Exhibit previous
four fault history
-
13-25
Previous Five
Fault History
Exhibit previous
five fault history
-
13-26
Previous Six
Fault History
Exhibit previous
six fault history
-

Other manuals for TECO E510s Series