33
Group 03: External Digital Input and
Output Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
03-05
Multi-Function
Terminal
Function
Setting-S6
37: Traversing
Operation
17
38: Upper
Deviation of
Traverse
Operation
39: Lower
Deviation of
Traverse
Operation
40: Switching
between Motor
1/Motor 2
41: PID Sleep
42: PG Disable
43: PG Integral
Reset
03-06
Multi-Function
Terminal
Function
Setting-S7
44: Mode
Switching
between Speed
and Torque
29*
45: Negative
Torque
Command
46: Zero-Servo
Command
47: Fire
mode(Forced
Operation mode)
48: KEB
Acceleration
49: Parameters
Writing Allowable
50: Unattended
Start Protection
(USP)
03-07 Reserved
03-08
(S1~S7) DI
Scan Time
0: Scan Time 4ms
1: Scan Time 8ms
1
03-09
Multi-Function
Terminal S1-
S4 Type
Selection
xxx0b: S1 A
Contact
xxx1b: S1 B
Contact
0000b
xx0xb: S2 A
Contact
xx1xb: S2 B
Contact
x0xxb: S3 A
Contact
x1xxb: S3 B
Contact
0xxxb: S4 A
Contact
1xxxb: S4 B
Contact
Group 03: External Digital Input and
Output Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
03-10
Multi-Function
Terminal S5-
S7 Type
Selection
xxx0b: S5 A
Contact
xxx1b: S5 B
Contact
0000b
xx0xb: S6 A
Contact
xx1xb: S6 B
Contact
x0xxb: S7 A
Contact
x1xxb: S7 B
Contact
0xxxb: S8 A
Contact
1xxxb: S8 B
Contact
03-11
Relay (R1A-
R1C) Output
0: During
Running
1
(Note4)
1: Fault Contact
Output
2: Frequency
Agree
3: Setting
Frequency
Agree
4: Frequency
Detection 1 (
03-13+03-14)
5: Frequency
Detection 2 (
03-13+03-14)
6: Automatic
Restart
7~8: Reserved
9: Baseblock
10~11: Reserved
12: Over-Torque
Detection
13: Current
Agree
14: Mechanical
Braking Control
(03-17~18)
15~17: Reserved
18: PLC status
19: PLC Control
Contact
03-12
(Note)
Photo-coupler
Output(DO1-
DOG)
20: Zero Speed
0
(Note4)
21: Inverter
Ready
22: Under
Voltage
Detection

Related product manuals