34
Group 03: External Digital Input and
Output Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
23: Source of
Operation
Command
24: Source of
Frequency
Command
25: Low Torque
Detection
26: Frequency
Reference
Missing
27: Timing
Function Output
28: Traverse
Operation UP
Status
29 : During
Traverse
Operation Status
30 : Motor 2
Selection
31 : Zero Speed
Servo Status
(Position Mode)
32: Communication
Control Contacts
33: RTC Timer 1
Note8
34: RTC Timer 2
Note8
35: RTC Timer 3
Note8
36: RTC Timer 4
Note8
37: PID
Feedback Loss
Detection Output
38: Brake
Release
39: Frequency
Detection 1
(dedicated for
Crane)
40: Frequency
Output
41: Position
Agree (Position
Mode)
42~44: Reserved
45: PID sleep
46~49: Reserved
50: Frequency
Detection 3 (
03-44+03-45)
51: Frequency
Detection 4 (
03-44+03-45)
52: Frequency
Detection 5 (
03-46+03-47)
Group 03: External Digital Input and
Output Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
53: Frequency
Detection 6 (
03-46+03-47)
54: Turn on
short-circuit
braking
Note1
57: Low Current
Detection
Note2
58: Frequency
Deceleration
Detection
Note4
59: Over-
Temperature
Detection
Note4
60: Life warning
period
(*11)
03-13
Frequency
Detection
Level
0.0~599.0 0.0
03-14
Frequency
Detection
Width
0.1~25.5 2.0
03-15
Current Agree
Level
0.1~999.9 0.1
03-16
Delay Time of
Current Agree
Detection
0.1~10.0 0.1
03-17
**Mechanical
Braking
Release
Level
0.00~599.00 0.00
03-18
**Mechanical
Braking Level
Set
0.00~599.00 0.00
03-19
Relay &DO1
Type
xxx0b: R1 A
Contact
xxx1b: R1 B
Contact
0000b *10
xx0xb: Photo-
coupler 1 A
Contact
xx1xb: Photo-
coupler 1 B
Contact
03-20 Reserved
03-21 Reserved
03-22
~
03-26
Reserved
03-27
UP/DOWN
Frequency
Hold/Adjust
Selection
0: Hold last set
frequency when
stopped
0
1: Set frequency
to 0 when
stopped