52
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
12-43 Inverter Status
0000 0000
1: Inverter ready
1: D uring running
1: D uring zero speed
1: D urin g speed agree
1 : D u rin g fa u lt d ete c tio n (m in o r fa u lt)
1: D uring fault detectio n (m ajo r fa u lt)
Reserved
-
12-44
Pulse Input
Frequency
Display the
frequency
value of pulse
input
-
12-45
Recent Fault
Message
Display current
fault message
-
12-46
Previous Fault
Message
Display
previous fault
message
-
12-47
Previous Two
Fault
Messages
Display
previous two
fault messages
-
12-48
Previous Three
Fault
Messages
Display
previous three
fault messages
-
12-49
Previous Four
Fault
Messages
Display
previous four
fault messages
-
12-50
DIO Status of
Current Fault
Display the
DI/DO status of
current fault
Description is
similar to 12-05
-
12-51
Inverter Status
of Current Fault
Display the
inverter status
of current fault
Description is
similar to 12-43
-
12-52
Trip Time 1 of
Current Fault
Display the
operation time
of current fault,
12-53 is the
days, while 12-
52 is the
remaining
hours.
-
12-53
Trip Time 2 of
Current Fault
-
12-54
Frequency
Command of
Previous Fault
Display
frequency
command of
previous fault
-
12-55
Output
Frequency of
Previous Fault
Display output
frequency of
previous fault
-
12-56
Output Current
of Previous
Fault
Display output
current of
previous fault
-
12-57
Output Voltage
of Previous
Fault
Display output
voltage of
previous fault
-
12-58
DC Voltage of
Previous Fault
Display DC
voltage of
previous fault
-
12-59
DIO Status of
Previous Fault
Display DI/DO
status of
previous fault
-
Group 12: Monitoring Parameters
Code
Parameter
Name
Setting Range Default
Attrib
ute
Description is
similar to 12-05
12-60
Inverter Status
of Previous
Fault
Display inverter
status of
previous fault
Description is
similar to 12-43
-
12-61
Trip Time 1 of
Last Fault
Display the
operation time
of last time’s
fault, 12-62 is
the days, while
12-61 is the
remaining
hours.
-
12-62
Trip Time 2 of
Last Fault
-
12-63
Recent
Warning
Messages
Display the
recent warning
messages
-
12-64
Previous
Warning
Message
Display the
previous
warning
message
-
12-65
Motor Start
Angle
0~360 -
12-66 Encoder Angle 0~360 -
12-67
Cumulative
Energy (KWHr)
0.0 ~ 999.9
12-68
Cumulative
Energy (MWHr)
0 ~ 60000
12-69
~
12-71
Reserved
12-72 RTC Date
12.01.01 ~
99.12.31
-
Note8
12-73 RTC Time
00:00 ~ 23:59
00:00 Note8
12-76
No-Load
Voltage Output
0.0~600.0 -
12-77 Reserved
12-78
Z-Phase Bias
Value
-9999~9999 -
12-79
Pulse Input
Percentage
0.0~100.0 -
12-80
AI1 Frequency
Command
0.0~599.0 0 Note2
12-81 Reserved
12-82 Motor Load 0~200.0 - Note4
12-85 Reserved
12-86
Error code of
Recent
Warning
0~65534 -
12-87
Capacitor
Lifetime
Percentage
0.0~200.0 0