Chapter 4 Software index
4-2
z Remote/Local change function
Local mode
Run command via RUN/STOP key on the keypad
Frequency command
When C41=000: only UP/DOWN key on the keypad can control and F05 setting has
no effect.
When C41=001: only VR on the keypad can control and F05 setting has no effect.
• Remote mode
Run command from Run parameter (F04) control setting
Frequency command from Frequency parameter (F05) control setting
Remote/Local change mode
on keypad is achieved by simultaneously pressing /RESET and
DATA/ENT. Each successive operation toggles between local and remote.
Note: The inverter must be stopped.