EasyManuals Logo

TECO JSDAP Series User Manual

TECO JSDAP Series
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
5-58
5-5-1 Automatic Gain Adjustment
This device provides ON-LINE Auto tuning, which can quickly and precisely measure Load Inertia and
adjust the Gain automatically. Setting is according to the table below:
Parameter Name Setting Description
Control
Mode
0 Auto tuning Disabled
Cn002.2
Auto tuning
1 Enable Auto tuning
Pe/Pi/S
When Cn002.2 is set to 0 (Auto tuning Disabled), following Gain adjust parameters must be set.
Parameter
Signal
Name
Cn025 Load Inertia Ratio
Sn211 Speed Loop Gain 1
Sn212 Speed-loop Integral time constant 1
Sn213 Speed loop Gain 2
Sn214 Speed loop Integral time constant 2
Pn310 Position Loop Gain 1
Pn311 Position Loop Gain 2
Pn312 Position Loop Feed-Forward Gain
When Cn002.2 is set to 1 auto tuning is enabled and the Servo controller will adjust the Servo Gain in
accordance with Cn026 (Rigidity Setting) and the measured Load Inertia Ratio by monitor parameter
Un-19 (Load Inertia Ratio), when the Load Inertia Ratio is becomes stable,
Then set 0 in Cn002.2 to cancel Auto tuning. At this moment, servo controller will record the measured
Load Inertia Ratio into Cn025 (Load Inertia Ratio).
If servo drive is used in a applications where there is no significant load variations, then monitor Un-19
(Load Inertia Ratio) if this is stable then it is recommended that Auto tuning is not used.

Table of Contents

Other manuals for TECO JSDAP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TECO JSDAP Series and is the answer not in the manual?

TECO JSDAP Series Specifications

General IconGeneral
BrandTECO
ModelJSDAP Series
CategoryServo Drives
LanguageEnglish

Related product manuals