EasyManuals Logo
Home>TECO>Servo Drives>JSDAP Series

TECO JSDAP Series User Manual

TECO JSDAP Series
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #164 background imageLoading...
Page #164 background image
5-78
8 160 160 30
9 200 200 25
A 250 250 20
Parameter Name Setting Description
0 Disabled
Cn029
Reset parameters
1 Reset all Parameters to default ( Factory setting)
Cn030
Servo motor model code Default
Servo model code can be display and checked with
parameter dn-08, refer 3-2-2 dn-08 table for more
information.
AttentionBefore operate your servo motor, check this
parameter setting is compatible for servo drive and
motor. If there has any incompatible problem contact
supplier for more information.
Pn307 Position complete value
0
50000
pulse
Set a value for In position output signal.
When the Position pulse error value is less then Pn307
output-contact INP (In position output signal) will be
activated.
Pn313
Position command
smooth
Acceleration/Deceleration
Time Constant
0
10000
ms
Set the time period for the Position command pulse
frequency to rise from 0 to 63.2%.
Pn324 Total Number Setting
1
64
Sets total number of tool turret
Pn325
The Location of Zero
CNC Tool Turret
0
131071
pulse
Sets the location of zero tool
Pn326
Reduction Gear Rate for
CNC Tools Turret
0
16383
rev
Sets reduction rate for turret.
Pn327
Rotation Speed of tool
turret switching
0
3000
rpm
Sets the rotation speed of tool terret swithing

Table of Contents

Other manuals for TECO JSDAP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TECO JSDAP Series and is the answer not in the manual?

TECO JSDAP Series Specifications

General IconGeneral
BrandTECO
ModelJSDAP Series
CategoryServo Drives
LanguageEnglish

Related product manuals