6-18
Communication
Address
Parameter Name & Functions Default Unit
Setting
Range
Control
Mode
RS232 RS485
Analog Speed Command offset adjust
Sn217
The offset amount can be adjusted by this parameter.
Input Voltage (V)
Offset
Voltage
Speed
Command (rpm)
0 mV
-10000
10000
S 534H 0211H
Analog speed command limited
Sn218
Setting Sn218 for limit the highest speed command of
analog input.
Rate
rpm x
1.02
rpm
100
4500
S C11H 0212H