46
Communication
Address
Parameter
Name & Functions Default
Unit
Setting
Range
Control
Mode
RS232
RS485
Analog Speed Command Ratio
Sn216
Slope of
voltage command / Speed command can be
adjusted.
105
-5-10
Input
Voltage (V)
Slope set by
Sn216
6000
3000
1500
-6000
-3000
-1500
Speed Command
(rpm)
Rate
rpm
rpm
/10V
100
6000
S 533H
0210H
Analog Speed Command offset adjust
Sn217
The offset amount can be adjusted by this parameter.
0 mV
-10000
10000
S 534H
0211H
Analog speed command limited
Sn218
Setting Sn218 for limit the highest speed
command of
analog input.
Rate
rpm x
1.02
rpm
100
4500
S C11H
0212H