Communication
Address
Parameter
Name & Function Default
Unit
Setting
Range
Control
Mode
RS232
RS485
Internal Position Command 32 -Rotation Number
Pn494
Please refer to Pn401
0 rev
-16000
16000
Pi 5E4H
077DH
Internal Position Command 32 - Pulse Number
Pn495
Please refer to Pn402
0 pulse
-131072
131072
Pi
5E6H
5E7H
077EH
077FH
Internal Position Command 32 - Move Speed
Pn496
Please refer to Pn403
0 rpm
0
3000
Pi 5E5H
0780H