15
Group 03- Multi function Digital
Inputs/Outputs
No. Description Range
Factory
Setting
Note
03-00
Multifunction
Input Term.
S1
0: Forward/Stop
Command or Run
/
Stop
0
03-01
Multifunction
Input Term.
S2
1: Reverse/Stop
Command Or
REV/FWD
1
03-02
Multifunction
Input Term.
S3
2
: Preset Speed 1
(5-02)
2
03-03
Multifunction
Input Term.
S4
3: Preset Speed 2
(5-03)
3
03-04
Multifunction
Input Term.
S5
4
: Preset Speed 4
(5-05)
17
6: Jog Forward
Command
7: Jog Reverse
Command
8: Up Command
9: Down Command
10: Acc/Dec 2
11: Acc/Dec
Disabled
12:
Main/Alternative
Run Command
s
elec
t
13:
Main/Alternative
Frequency
Command selec
t
14: Rapid Stop
( Decel to stop)
15: Base Block
16: Disable PID
Function
17: Rese
t
18: Auto Run
Mode enable
03-05
Reserved
03-06
Up/Down
f
requency
band
0.00~5.00
0.00
03-07
Up/Down
Frequency
modes
0: Preset
f
requency is held
as the inverter
s
tops, and the
UP/Down function
is disabled.
0
1: Preset
f
requency is reset
t
o 0 Hz as the
inverter stops.
2
: Preset
f
requency is held
as the inverter
s
tops, and the
UP/Down is
available.
Group 03- Multi function Digital
Inputs/Outputs
No. Description Range
Factory
Setting
Note
03-08
S1~S5 scan
confirmation
1~200. Number
f Scan cycles
10
03-09
S1~ S5
s
witch type
s
elec
t
x
xxx0:S1 NO
x
xxx1:S1 NC
00000
x
xx0x:S2 NO
x
xx1x:S2 NC
x
x0xx:S3 NO
x
x1xx:S3 NC
x
0xxx:S4 NO
x
1xxx:S4 NC
0xxxx:S5 NO
1xxxx:S5 NC
03-10
Reserved
03-11
Output
Relay(RY1)
0: Run
1
1: Fault
2
: Setting
Frequency
Reached
3: Frequency
Reached
(3-13±3-14)
4
: Output
Frequency
Detection1(> 3-13)
5: Output
Frequency
Detection2(< 3-13)
6: Auto-Restart
7: Momentary AC
Power Loss
8: Rapid Stop
9: Base Block
10: Motor Overload
Protection(OL1)
11: Drive Overload
Protection(OL2)
12: Reserved
13: Output Current
Reached
14: Brake Control
15: PID feedback
d
isconnection
d
etection
03-12
Reserved
03-13
Output
f
requency
d
etection
level (Hz)
0.00~599.00 0.00 *1
03-14
Frequency
Detection
band
0.00~30.00 2.00 *1
03-15
Output
Current
Detection
Level
0.1~999.9 0.1
03-16
Output
Current
Detection
0.1~10.0 0.1

Other manuals for TECO L510S Series