19
Group 07- Start/Stop command setup
No. Description Range
Factory
Setting
Note
Brake Start
Frequency
(Hz) In Stop
mode
07-07
DC Injection
Brake Level
(%) In stop
mode
0 ~ 20 (Frame1/2).
Based on the 20%
o
f maximum outpu
t
v
oltage 5
0 ~ 100 (Frame3/4)
based on the rated
current 50
07-08
DC Injection
Brake Time
(Seconds)
In stop
mode
0.0 ~ 25.5 0.5
07-09
Stopping
Method
0: Deceleration to
s
top
1: Coast to stop
0
07-10
DC Braking
Level at
Start
0 ~ 20 (Frame1/2).
Based on the 20%
o
f maximum outpu
t
v
oltage
0
0 ~ 100 (Frame3/4)
based on the rated
current
50
07-11
DC Braking
T
ime at Star
t
0.0~25.5 0.0
07-12
Run
Command
Retention
0: Run command
retention during
power loss
1: Run command
not retained during
power loss
1
Note:
Set 14-00=0, 07-12 will be set to 1 automatically.
Set 14-00=1, 07-12 will be set to 0 automatically.
Group 08- Drive & Motor Protection
functions
No. Description Range
Factory
Setting
Note
08-00
T
rip
Prevention
Selection
x
xxx0: Enable Trip
Prevention During
A
cceleration
x
xxx1: Disable Trip
Prevention During
A
cceleration
x
xx0x: Enable Trip
Prevention During
Deceleration
x
xx1x: Disable Trip
Prevention During
Deceleration
x
x0xx: Enable Trip
Prevention in Run
Mode
x
x1xx: Disable Trip
00000
Group 08- Drive & Motor Protection
functions
No. Description Range
Factory
Setting
Note
Prevention in Run
Mode
x
0xxx: Enable over
v
oltage Prevention
in Run Mode
x
1xxx: Disable
o
ver voltage
Prevention
in Run Mode
08-01
T
rip
Prevention
Level
During
A
cceleration
(%)
50 ~ 200 by series
08-02
T
rip
Prevention
Level
During
Deceleration
(%)
50 ~ 200 by series
08-03
T
rip
Prevention
Level In
Run Mode
(%)
50 ~ 200 by series
08-04
o
ver voltage
Prevention
Level in Run
Mode
2
00V: 350.0~390.0
4
00V: 700.0~780.0
380.0/76
0.0
*1
08-05
Electronic
Motor
Overload
Protection
Operation
Mode
x
xxx0: Disable
Electronic Motor
Overload
Protection
00001
x
xxx1: Enable
Electronic Motor
Overload
Protection
x
xx0x: Motor
Overload Cold
Start
x
xx1x: Motor
Overload Hot Start
x
x0xx: Standard
Motor
x
x1xx: Invertor
Duty Motor ( Force
V
ent)
08-06
Operation
A
fter
Overload
Protection is
A
ctivated
0: Coast-to-Stop
fter Overload
Protection is
A
ctivated
1: Drive Will Not
T
rip when
Overload
Protection is
ctivated (OL1)
0

Other manuals for TECO L510S Series

Related product manuals