Horsepower Power source Max. Volts Amps
0.5/1/2/3 200 – 240V
1/2 380 – 480V
300 20
5/7.5/10 200 –240V
3/5/7.5/10 380 –480V
600 40
15/20 200 –240V
15/20/25/30 380 –480V
600 60
25/30 200 –240V 600 100
Note: Nominal values of input and output signals (TM2) – follow the specifications of class 2
wiring.
2. Fuse types
To protect the inverter most effectively, use fuses with current-restraint function.
Horsepower Power source Max. Rated fuse specifications
2 15A, 600VAC, 100KA, I.R.
3 20A, 600VAC, 100KA, I.R.
5 30A, 600VAC, 100KA, I.R.
7.5/10 60A, 600VAC, 100KA, I.R.
15/20 100A, 600VAC, 100KA, I.R.
25/30
200 – 240V
150A, 600VAC, 100KA, I.R.
1 5A, 600VAC, 100KA, I.R.
2 10A, 600VAC, 100KA, I.R.
3 15A, 600VAC, 100KA, I.R.
5 20A, 600VAC, 100KA, I.R.
7.5/10 40A, 600VAC, 100KA, I.R.
15/20 70A, 600VAC, 100KA, I.R.
25/30
380 – 480V
100A, 600VAC, 100KA, I.R.