EasyManua.ls Logo

TECO SPEECON GS510 - User Manual

TECO SPEECON GS510
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INVERTER
INSTRUCTION MANUAL
220V Class 3Φ 25~100HP
440V Class 3Φ 25~500HP
Please hand this manual to the end-users. It will be of
great help for their daily operation, maintenance,
inspection and troubleshooting.
7200GS/GS510
SPEECON

Questions and Answers

  • В
    ВикторJun 30, 2026
    GS510BA0075AZ-A "fault over current"

    Summary

    BEFORE INSTALLATION & USE

    WARNING

    1. WIRING

    1.1 NOTES ON WIRING TO PERIPHERAL UNITS

    Guidance on connecting input/output peripherals and components.

    1.2 CONNECTION DIAGRAM

    Diagram illustrating main and control circuit interconnections for the inverter.

    1.3 TERMINAL FUNCTION

    Details the functions of main and control circuit terminals.

    1.4 WIRING PARTS

    Recommended wiring parts like MCCBs, cables, and contactors for 220V/440V classes.

    GROUNDING (PE: Protective Earth)

    Guidelines for proper grounding of the inverter unit.

    1.5 SPECIFICATIONS

    CHARACTERISTICS

    1.6 DIMENSIONS

    2. DESCRIPTION OF USING 7200 GS;GS510

    2.1 Using LCD (OR LED) digital operator

    Details on using LCD and LED digital operators, including modes and display.

    2.3 Parameter description

    Description of the four user parameter groups (An, Bn, Sn, Cn).

    3. SETTING USER CONSTANT

    3.1 Frequency command (in Multi-speed operation) An-

    Details on setting frequency commands for multi-speed operation.

    3.2 Parameters Can Be Changed during Running Bn-

    Parameters that can be modified while the inverter is running.

    3.3 Control Parameters Cn-

    Control parameters affecting inverter operation and settings.

    3.4 System Parameters Sn-

    System parameters for configuration and operation status.

    3.5 Monitoring Parameters Un-

    Parameters for monitoring inverter status and performance.

    3.6 Monitoring Parameters Hn-

    Parameters for monitoring inverter input/output interface status in PRGM mode.

    3.7 Order Parameters On-

    Order parameters, typically factory-set for optimal performance.

    4. FAULT DISPLAY AND TROUBLESHOOTING

    B.) Warning and Self-Diagnosis Functions

    Explains warning indicators and self-diagnosis functions of the inverter.

    TECO SPEECON GS510 Specifications

    General IconGeneral
    Cooling MethodForced air cooling
    Output Frequency0-400Hz
    Control MethodVector Control
    Protection FeaturesOvervoltage, Undervoltage, Overcurrent, Short Circuit, Overheating
    Communication InterfaceModbus
    Operating Temperature-10°C to +50°C
    Storage Temperature-20°C to +60°C
    Humidity5-95% (Non-condensing)
    AltitudeUp to 1000m
    Input Voltage3-phase 380~480VAC -15%~+10%, 50/60Hz ±5%

    Related product manuals