Operational Environment
The installation site of the T-verter is very important. It relates directly to the functionality and the life
span of your T-verter. Please carefully choose the installation site to meet the following
requirements:
z Mount the unit vertically
z Environment temperature: -10
O
C ~ +40
O
C(with cover removed: -10
O
C ~ +50
O
C)
z Avoid placing close to any heating equipment
z Avoid water dripping or humid environment
z Avoid direct sunlight
z Avoid oil or salty corrosive gas
z Avoid contacting corrosive liquid or gas
z Prevent foreign dusts, flocks, or metal scraps from entering interior
z Avoid electric-magnetic interference (soldering or power machinery)
z Avoid vibration, if vibration cannot be avoided, an anti-rattle mounting device should be
installed to reduce vibration.
z If the T-verter is installed in an enclosed control panel, please add additional cooling using an
external fan. This will allow additional airflow and cooling.
z Placement of external fans should be directly over the top of the T-verter.
z For proper Installation of the T-verter you must place the front side of the T-verter facing front
and the top of the T-verter in the up direction for better heat dissipation.
z Installation must be compliant to the following requirements.