HC2-E1000 SERIES
- 14 -
Code
Parameter Settings Default
F120
Jog frequency 0.0 ~ 10.0Hz 0.2Hz *2Hz
F121
Jog acceleration time 0.01s ~ 60.00s 1s
F2 group – Input / Output parameters
Code
Parameter Settings Default
F200
Control mode
0: General
1: Knitting
0
F201
X1 terminal
1: Speed terminal 1
2: Speed terminal 2
3: Speed terminal 3
14: Instant stop
(normal open)
15: Instant stop
(normal close)
1
F202
X2 terminal 2
F203
X3 terminal 3 *16
F204
X4 terminal 4: Jog 4 *0
F216
Multi-speed frequency 1
0.0 ~ 400.0Hz
5Hz
F220
Multi-speed frequency 2 10Hz
F224
Multi-speed frequency 3 15Hz
F228
Multi-speed frequency 4 20Hz
F232
Multi-speed frequency 5 30Hz
F236
Multi-speed frequency 6 40Hz
F240
Multi-speed frequency 7 50Hz
F3 group – Advanced parameters
Code
Parameter Settings Default
F301
Carrier frequency
adjustment
0.0 ~ 12KHz
*7KHz
F306
Reverse mode 0: enable 1: disable 0
F320
Unlock parameters
0: All parameters unlocked
2: Only this group unlocked
F321
Initialization
parameters
0: No action
1: Clear fault records