Troubleshooting
Troubleshooting
Problem Probable cause(s) Remedy
No response from xture
when power is applies
No power to xture Check power cables
Primary fuse blown Replace fuse
Secondary fuse blown Replace fuse
Fixture resets but does
not respond correctly to
controller(DMX mode oper-
ation)
Controller not connected Connect controller
Incorrect addressing of the
xtures
Check address setting on xture and controller
Bad data link connection
Inspect cables and correct poor connections and/
or broken cables.
Conict between tracking and
vector control
Eliminate scene cross-fade on controller
Data link not terminated Insert termination plug in output of last xture
Defective xture or 2 devices
transmitting on link
Bypass xtures one at a time until normal oper-
ation is regained:unplug both connectors and
connect them directly together
Colors cannot be mixed Random color mixing is on Turn o random color mixing
Fixture does not reset
correctly
Electronic or mechanical failure Contact service technician
No light, lamp cuts out
intermittently,or burns out
too quickly
Lamp missing or blown Disconnect xture and replace lamp
Fixture or lamp is too hot
Allow xture to cool. If problem persists,contact
service technician