6.9 CLEANING THE PELLET SUPPLY PIPE
Clean the pellet supply pipe once a week with a stiff round brush (figure 37). The
pellet supply pipe is located in the stove’s combustion chamber. Creosote can build
up in the supply pipe and contaminate it to such an extent that it can get blocked
by pellets.
6.10 MAINTENANCE TO BE PERFORMED BY AN AUTHORISED TECHNICIAN
Task Frequency*
General professional inspection
and servicing of the stove (& the
flue)
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Clean/sweep the flue gas system Twice a season; the first time at the start of
the season
Replacement of parts that are not
mentioned in this manual
When damage is identified
Check the connection between the
stove and chimney/the flue
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
All other service work not specifi-
cally mentioned in this manual.
Once a season at the start of the season
Clean the room blower/flue blow-
er
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Cleaning the stove inside and out Once a season or after 900 combustion
hours when the stove displays SERV
Lubricate the pellet auger gear
unit
Once a season at the end of the season
Clean the smoke chamber Once a season; at the end of the season or
after 900 combustion hours when the stove
displays SERV
Check the ignition element Once a season
Clean the air side of the heat ex-
changer
Once a season or after 900 combustion
hours when the stove displays SERV
Clean the flue side of the heat ex-
changer
Once a season or after 900 combustion
hours when the stove displays SERV
Check the electrical parts such as
the PCB, the wiring, the sensors
and safety devices.
Once a season or after 900 combustion
hours when the stove displays SERV
Check the silicon hoses on the pres-
sure sensor
Once a season or after 900 combustion
hours when the stove displays SERV
Check the door seal and replace if
necessary.
Twice a season; the first time at the start of
the season or after 900 combustion hours
when the stove displays SERV
Test the stove at all 5 combustion
levels
Once a season or after 900 combustion
hours when the stove displays SERV
Test the safety devices Once a season or after 900 combustion
hours when the stove displays SERV
(*) The specified frequency is a minimum. Local law and/or your insurance contract