4
77
K TECHNICAL DATA
To be used as indication, subject to modifications
Model TP 1020
Cooling capacity* W 2000
EE Class A
EER* 2.61
Power consumption kW 0.766
Current nom. A 3.5
Mains V/Hz/PH 230 / 50 / 1
Air delivery max. m3/h 370
Dehumidification max. ** L/24h 20
Room size m3 50-65
Compressor type rotary
Refrigerant type/gr R-410A / 350
Thermostat range °C 18 - 32
Fan speeds 2
Max. sound pressure level dB(A) 52-54
Dimensions (w x h x d) mm 305 x 752 x 384
Nett weight kg 21
Unit protection IP X0
Remote control yes
Fuse rating 50T, 250 VAC, 2A
* Conform EN 14511-2007
** Moisture removal at 32°C, 80% RH
Environmental information: This equipment contains fluorinated greenhouse
gases covered by the Kyoto Protocol. It should only be serviced or dismantled by
professional trained personnel.
This equipment contains R410A refrigerant in the amount as stated in the table
above.DonotventR410Aintoatmosphere:R410A,isafluorinatedgreenhouse
gaswithaGlobalWarmingPotential(GWP)=1975.
Waste electrical products should not be disposed with household waste. Please
recycle where facilities exist. Check with your local authority or retailer for
recycling advice.
man_TP1020.indd 77 10-12-10 15:17