INCIDENTS WHEN OPERATING THE PYROLYTIC FUNCTION
INCIDENT CAUSE SOLUTION
My accessories and shelf
supports are damaged.
You have not removed the
accessories and supports during
the pyrolytic cleaning cycle.
You must replace them and
remove them in later cleaning
cycles.
The enamel colour has
changed and stains have
appeared.
The chemical composition of
some foodstuffs may cause
changes in the enamel.
This is normal and does not
damage the properties of the
enamel.
The oven door is locked, pilot
light is lit up but the oven
is not hot.
You have turned the control
dial to position and no
other additional operation has
been performed.
Switch off the oven and follow
the instructions to unlock the
door in the first 30 minutes at
a low temperature.
Next, select the pyrolytic
function, carefully following the
instructions.
I have turned the control dial to
position and selected a
pyrolisis programme (P1, P2 or
P3) but the pilot light has
not lit up and the oven is not
heating up.
The oven door is not closed
properly, so the door cannot
be locked.
Check the door and make
sure that it is closed properly.
I have turned the control dial to
position and selected a
pyrolisis programme (P1, P2 or
P3) but the pilot light has
not lit up and the oven is not
heating up.
The door switch is not working
even though the door is
properly closed.
Call Technical Assistance
Service as there is a fault in
the door switch.
I have programmed the
pyrolysis function, the oven is
working properly but pilot light
is not lit up.
Pilot light does not work
properly.
Call the Technical Assistance
Service.
The pyrolysis programme has
ended and the oven is cold,
but the door is locked and
symbol is flashing.
You did not turn the control
dial to position when the
pyrolysis programme ended.
1. Turn the control dial to
position and wait for 1
minute.
2. Turn the control dial to
position and wait for 1
minute.
3. Turn the control dial to
position again and wait
until pilot light turns off.
3172755-000 EPIFA 26/05/14 09:30 Página 28