Boiler Control 274
1 of 44 © 2012 274_D - 11/12
The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint
operation with priority. When operating as a tN4 System Control, the 274 can connect with up to 24 tN4 devices on a single
boiler bus. The 274 has primary pump sequencing capabilities along with a flow proof or combustion air damper proof
demand.
tN4 Compatible
24 Hour, 5-1-1, 7 Day Schedule
Flow or Combustion Air Proof
Four On/Off Boilers
Equal Run Time Rotation
Primary Pump Sequencing
DHW Operation
Optional DHW Sensor
Setpoint Operation
Additional functions include:
Input
Universal
Sensor
Included
Input
Universal
Sensor
Included
tN4
Boiler
Bus
Input
Outdoor Sensor
Included
OR
0-10 or 2-10 V (dc)
from EMS
Output
Up to 4
On/Off Boilers
Input
115 V (ac)
Power Supply
Input
Flow OR
C.A. Proof
Output
Up to 2
Boiler Pumps
Output
DHW Pump
OR
Primary Pump
Output
Combustion
Air Damper
OR Alert
OR
OR
Output
Primary
Pump
Input
DHW OR
Setpoint
Demand
Signal
Input
Boiler
Demand
Signal
Primary
DHW
1
13
24
VIEW
Demands
Setback
Boiler Control 274
One tN4, Four Stage Boiler & DHW / Setpoint
Menu Item
Test
Boiler Demand
DHW / Setpoint Demand
Proof Demand
EMS Input Signal
Priority Override
Power 115 V ±10% 60 Hz 7 VA, 1150 VA max.
Relays 230 V (ac) 5 A 1/3 hp
Demands 20 to 260 V (ac) 2 VA
Made in Canada by
tekmar Control Systems Ltd
tektra 1020-02
Meets Class B:
Canadian ICES
FCC Part 15
For maximum heat,
press and hold Test
button for 3 seconds.
not testing
testing
testing paused
off
red
red
Off
EMS
Rotate
Fixed Last
Pump Sequencer
Exercise
Off
Date Code
H2050A
Signal wiring must be rated at least 300 V.
DHW
23
/Setp
Com
24
Dem
Pr.
25
Dem
2513
+
46
BRet/
ComtN4
Boil
OutCom
Prim
P1 L N
20
Power
222187
Do not apply power
18
DHW
/ P2
17 191091211 1413 1615
Fixed Lead
First On / Last Off
First On / First Off
Relay
1
Relay
2
Relay
3
Relay
4
C.A. /
Alert
Boiler
Demand
Sup
DHW
Zone Load Shedding
1 Up to 4 On/Off Boilers
2 Up to 2 On/Off Boilers & 2 Pumps
3 Up to 2 Lo/Hi Boilers
4 1 Lo/Hi Boiler & 1 Pump
5 1 Three Stage Boiler & Pump
6 1 Four Stage Boiler
Modes
Question and Answer IconNeed help?

Do you have a question about the Tekmar 274 and is the answer not in the manual?

Summary

Using the Data Brochure

User Interface and Navigation

Explains the control's display, buttons, and menu system.

Control Display and Symbols

Display Fields and Symbol Descriptions

Details on display segments and symbol meanings.

Sequence of Operation

Access Level and Boiler Demand

Access control, boiler demand input, and outdoor reset.

Heating System Configuration

Terminal Unit and Room Settings

Adjusts heating curve based on terminal unit and room temp.

Boiler Operation Settings

Boiler Design, WWSD, and Operation Modes

Configures design temps, WWSD, and boiler operation modes.

Boiler Performance Tuning

Boiler Limits, Stage Delay, Mass, Rotation, Fixed Last

Settings for boiler limits, stage delay, mass, rotation, and fixed last.

Combustion Air, Alerts, and Boiler Control Logic

C.A.;Alert Relay, Boiler Differential, Staging, Fire Delay

Settings for C.A./Alert relay, boiler differential, staging, and fire delay.

DHW Operation Basics

DHW Demand Sources and Configuration

How DHW demands are received and configured.

DHW Operation Modes

DHW Modes 1, 2, OFF and Settings

Parallel DHW modes, differential, and unoccupied settings.

Advanced DHW Operation Modes

DHW Modes 3, 4, 5, and 6

Primary/secondary and dedicated DHW modes.

DHW Priority and Boiler Interaction

DHW Priority Override, Purge, and Low Temp Boilers

Settings for DHW priority, purge, and low temp boiler considerations.

Setpoint Operation Modes

Setpoint Demand, Modes, Priority, and Unoccupied

Setpoint demand, modes, priority, and unoccupied settings.

Advanced Setpoint Operation

Setpoint Modes 3, 4, Priority Override, and Post Purge

Setpoint modes, priority override, and post purge settings.

Energy Management System (EMS) Integration

EMS Input Signal and Offset Configuration

Configuring EMS input signals and fine-tuning.

Pump Operation and Flow Proof

Primary Pump Operation, Stand-by Logic, and Flow Proof

Primary pump operation, stand-by logic, and flow proof requirements.

Pump Control and System Exercising

Pump Settings, Exercising, and Time Clock

Settings for pump proof delay, rotation, purge, exercising, and time clock.

Schedule and Boost Configuration

Schedule Setup, Types, Modes, and Boost

Configuring schedules, types, modes, and boost function.

tekmarNet4 System Integration

tN4 Communication, Load Shedding, Cycle Length, Temp Feedback, Device Count

tN4 system integration features including communication, load shedding, cycle length, feedback, and device count.

Installation Procedures

Installation Preparation, Mounting, and Wiring

Procedures for preparing, mounting, and wiring the control.

Input Wiring Connections

Demand, EMS, and tN4 Input Wiring

Wiring for various demand inputs, EMS, and tN4 devices.

Sensor and Output Wiring

Sensor and Pump;Boiler Pump Output Wiring

Connecting sensors and wiring primary/boiler pump outputs.

Wiring Verification and Testing

Relay, Network, and EMS Input Testing

Testing relays, tN4 network continuity, and EMS voltage.

Component Wiring and Input Tests

Sensor, Pump, Relay, and Input Power Tests

Testing sensors, pumps, relays, and control input power.

Control Settings and DIP Switches

Demand Testing, Control Cleaning, and DIP Switch Configuration

Testing demands, cleaning control, and configuring DIP switches.

DIP Switch Operation Modes

Configuring Rotation, Lead, Sequencing, and First On;Off DIP Switches

Setting DIP switches for rotation, lead, sequencing, and firing order.

Display Menu Navigation - View Menu (Part 1)

Viewing System Temperatures and Status

Displays outdoor air, boiler supply, target, and DHW temps.

Display Menu Navigation - View Menu (Part 2)

Viewing Boiler and Pump Running Times

Displays running times for boilers and pumps.

Adjust Menu - Core Settings

Mode, Room Temps, EMS, Boost, Boiler 1 Settings

Basic settings for operation mode, room temps, EMS, boost, and Boiler 1.

Adjust Menu - Boiler and System Settings

Boiler 2-4, Design Temps, Terminal Unit, Boiler Limits

Settings for boilers 2-4, design temps, terminal unit, and boiler limits.

Adjust Menu - Boiler Control Logic

Boiler Differential, Staging, Fire Delay, Proof Demand, Damper Delay

Settings for boiler differential, staging, fire delay, proof demand, and damper delay.

Adjust Menu - DHW and Pump Configuration

Boiler Mass, Pump Purge, Cycle Length, DHW Mode, Sensor, Temp Settings

Settings for boiler mass, pump purge, cycle length, DHW mode, sensor, and temps.

Adjust Menu - DHW and Setpoint Configuration

DHW Differential, Exchange, Boiler, Setpoint Mode and Temp Settings

Settings for DHW differential, exchange, boiler, setpoint modes, and temperatures.

Adjust Menu - System and Safety Settings

Zone Load Shedding, Priority, WWSD, Pump Rotation, Alarm

Settings for zone load shedding, priority, WWSD, pump rotation, and boiler alarm.

Time and Date Configuration

Setting Time, Date, DST, and Year

Configuring current time, date, DST, and year.

Schedule Configuration

Heat Schedule, Type, Mode, and Event Time Setup

Configuring heat schedule, type, mode, and event times.

Schedule Event Time Configuration

Setting Schedule Event Times (All Days, Weekdays, Weekends)

Configuring event times for different day groupings.

Daily Schedule Event Time Configuration

Setting Specific Weekday Schedule Event Times

Configuring event times for specific weekdays.

Miscellaneous Control Settings

Access Level, Units, Device Count, Defaults, Type

Configuring access level, units, device count, defaults, and type.

Control Testing and Special Modes

Test Sequence, Max Heat, and Zone Test

Performing test sequences, Max Heat, and Zone Test modes.

Control Error Messages (Part 1)

Configuration and Communication Errors

Errors related to menu settings and tN4 bus communication.

Control Error Messages (Part 2)

Schedule, Sensor, and Device Errors

Errors related to schedules, sensors, and device communication.

Control Error Messages (Part 3)

Pump, Damper, Boiler Alarm, and DHW Errors

Errors related to pumps, dampers, boiler alarms, and DHW.

Technical Data and Warranty

Product Specifications and Limited Warranty

Technical data and warranty information for the Boiler Control 274.

Summary

Using the Data Brochure

User Interface and Navigation

Explains the control's display, buttons, and menu system.

Control Display and Symbols

Display Fields and Symbol Descriptions

Details on display segments and symbol meanings.

Sequence of Operation

Access Level and Boiler Demand

Access control, boiler demand input, and outdoor reset.

Heating System Configuration

Terminal Unit and Room Settings

Adjusts heating curve based on terminal unit and room temp.

Boiler Operation Settings

Boiler Design, WWSD, and Operation Modes

Configures design temps, WWSD, and boiler operation modes.

Boiler Performance Tuning

Boiler Limits, Stage Delay, Mass, Rotation, Fixed Last

Settings for boiler limits, stage delay, mass, rotation, and fixed last.

Combustion Air, Alerts, and Boiler Control Logic

C.A.;Alert Relay, Boiler Differential, Staging, Fire Delay

Settings for C.A./Alert relay, boiler differential, staging, and fire delay.

DHW Operation Basics

DHW Demand Sources and Configuration

How DHW demands are received and configured.

DHW Operation Modes

DHW Modes 1, 2, OFF and Settings

Parallel DHW modes, differential, and unoccupied settings.

Advanced DHW Operation Modes

DHW Modes 3, 4, 5, and 6

Primary/secondary and dedicated DHW modes.

DHW Priority and Boiler Interaction

DHW Priority Override, Purge, and Low Temp Boilers

Settings for DHW priority, purge, and low temp boiler considerations.

Setpoint Operation Modes

Setpoint Demand, Modes, Priority, and Unoccupied

Setpoint demand, modes, priority, and unoccupied settings.

Advanced Setpoint Operation

Setpoint Modes 3, 4, Priority Override, and Post Purge

Setpoint modes, priority override, and post purge settings.

Energy Management System (EMS) Integration

EMS Input Signal and Offset Configuration

Configuring EMS input signals and fine-tuning.

Pump Operation and Flow Proof

Primary Pump Operation, Stand-by Logic, and Flow Proof

Primary pump operation, stand-by logic, and flow proof requirements.

Pump Control and System Exercising

Pump Settings, Exercising, and Time Clock

Settings for pump proof delay, rotation, purge, exercising, and time clock.

Schedule and Boost Configuration

Schedule Setup, Types, Modes, and Boost

Configuring schedules, types, modes, and boost function.

tekmarNet4 System Integration

tN4 Communication, Load Shedding, Cycle Length, Temp Feedback, Device Count

tN4 system integration features including communication, load shedding, cycle length, feedback, and device count.

Installation Procedures

Installation Preparation, Mounting, and Wiring

Procedures for preparing, mounting, and wiring the control.

Input Wiring Connections

Demand, EMS, and tN4 Input Wiring

Wiring for various demand inputs, EMS, and tN4 devices.

Sensor and Output Wiring

Sensor and Pump;Boiler Pump Output Wiring

Connecting sensors and wiring primary/boiler pump outputs.

Wiring Verification and Testing

Relay, Network, and EMS Input Testing

Testing relays, tN4 network continuity, and EMS voltage.

Component Wiring and Input Tests

Sensor, Pump, Relay, and Input Power Tests

Testing sensors, pumps, relays, and control input power.

Control Settings and DIP Switches

Demand Testing, Control Cleaning, and DIP Switch Configuration

Testing demands, cleaning control, and configuring DIP switches.

DIP Switch Operation Modes

Configuring Rotation, Lead, Sequencing, and First On;Off DIP Switches

Setting DIP switches for rotation, lead, sequencing, and firing order.

Display Menu Navigation - View Menu (Part 1)

Viewing System Temperatures and Status

Displays outdoor air, boiler supply, target, and DHW temps.

Display Menu Navigation - View Menu (Part 2)

Viewing Boiler and Pump Running Times

Displays running times for boilers and pumps.

Adjust Menu - Core Settings

Mode, Room Temps, EMS, Boost, Boiler 1 Settings

Basic settings for operation mode, room temps, EMS, boost, and Boiler 1.

Adjust Menu - Boiler and System Settings

Boiler 2-4, Design Temps, Terminal Unit, Boiler Limits

Settings for boilers 2-4, design temps, terminal unit, and boiler limits.

Adjust Menu - Boiler Control Logic

Boiler Differential, Staging, Fire Delay, Proof Demand, Damper Delay

Settings for boiler differential, staging, fire delay, proof demand, and damper delay.

Adjust Menu - DHW and Pump Configuration

Boiler Mass, Pump Purge, Cycle Length, DHW Mode, Sensor, Temp Settings

Settings for boiler mass, pump purge, cycle length, DHW mode, sensor, and temps.

Adjust Menu - DHW and Setpoint Configuration

DHW Differential, Exchange, Boiler, Setpoint Mode and Temp Settings

Settings for DHW differential, exchange, boiler, setpoint modes, and temperatures.

Adjust Menu - System and Safety Settings

Zone Load Shedding, Priority, WWSD, Pump Rotation, Alarm

Settings for zone load shedding, priority, WWSD, pump rotation, and boiler alarm.

Time and Date Configuration

Setting Time, Date, DST, and Year

Configuring current time, date, DST, and year.

Schedule Configuration

Heat Schedule, Type, Mode, and Event Time Setup

Configuring heat schedule, type, mode, and event times.

Schedule Event Time Configuration

Setting Schedule Event Times (All Days, Weekdays, Weekends)

Configuring event times for different day groupings.

Daily Schedule Event Time Configuration

Setting Specific Weekday Schedule Event Times

Configuring event times for specific weekdays.

Miscellaneous Control Settings

Access Level, Units, Device Count, Defaults, Type

Configuring access level, units, device count, defaults, and type.

Control Testing and Special Modes

Test Sequence, Max Heat, and Zone Test

Performing test sequences, Max Heat, and Zone Test modes.

Control Error Messages (Part 1)

Configuration and Communication Errors

Errors related to menu settings and tN4 bus communication.

Control Error Messages (Part 2)

Schedule, Sensor, and Device Errors

Errors related to schedules, sensors, and device communication.

Control Error Messages (Part 3)

Pump, Damper, Boiler Alarm, and DHW Errors

Errors related to pumps, dampers, boiler alarms, and DHW.

Technical Data and Warranty

Product Specifications and Limited Warranty

Technical data and warranty information for the Boiler Control 274.

Tekmar 274 Specifications

General IconGeneral
CategoryController
Input Voltage24 VAC
Output Voltage24 VAC
DisplayLCD
Operating Temperature32 to 122°F (0 to 50°C)

Related product manuals