Tekmar Eight Stage Boiler Control 258 User Manual

Tekmar Eight Stage Boiler Control 258
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
C
26 27
Zone
10K
0.4
2.0
3.6
Heating Curve
22°F
242
DemR
12 5678
Pmp
Eight Stage Boiler Control 258
Dem
HeatSystem
Pmp
910 28
Sen
Com
Sw
UnO
29 30
Sen
Sup Out
Power
Minimum
120°F
Off 170
Boiler
Differential
80
Power Supply: 24V 60Hz 5VA
Relay capacities: 24V 10A
Test
No power here
Maximum 24 volts
34
Stage
Sen
H1077
Date
S/N
221092
1234567
1
1
11 12
Stage
2
2
13
14
Stage
3
3
15 16
Stage
4
4
Power
Heat
Demand
Minimum
WWSD
Pump
Stage 1
Stage 2
Comb. Air
Stage 3
Stage 6
Stage 5
Stage 8
Stage 7
Stage 4
Menu
Item Override
Setpoint
S
PRGM
TEMP
FC
Actual
Supply
Target
Supply
TIME
USE
AMPM
UNOCC
OVR
MTWTFS
OUTSIDE
ROOM
1
2
17
18 19 20
21
22 23
Air
Comb.
24 25
Stage
5
5
Stage
6
6
Stage
7
7
N/C
8
8
N/OCom
M
tekmar
Zone
Control
Auto
Stage
1 2 3 4 5 6 7 8
Perm.
Demand
Ext. timer
Fixed last
Int. timer
Lo-Hi fire
Fixed lead
Off
1
2
3
4
5
6
7
8
9
External
Demand
Off
1
2
3
4
5
6
Stpnt
Reset
Rotate
8
- Data Brochure
Eight Stage Boiler Control 258
D 258
07/93
Terminal Plugs:
Power and out-
put connections
LEDs and
LCD screen;
display of times
& temperatures
Boiler
Differential
setting
Heating Curve
setting
Minimum
Supply setting
Terminal Plug:
Sensor and
timer inputs
Test button &
LED to test
main control
functions
System Pump
is on
Programming
buttons
Eight Stage Boiler Control 258
Power
Heat
Demand
Minimum
WWSD
Pump
Stage 1
Stage 2
Comb. air
Stage 3
Stage 6
Stage 5
Stage 8
Stage 7
Stage 4
Menu
Item Override
Setpoint
Actual
Supply
Target
Supply
S
PRGM
TEMP
FC
TIME
USE
AMPM
UNOCC
OVR
MTWTFS
OUTSIDE
ROOM
1
2
Operating Mode
selector switches
Heating
is required
24Vac power
supply is on
Combustion air
damper is open
System is in
Warm Weather
Shut Down
Control is
maintaining
Minimum Supply
Input: Outdoor
Sensor 070
Included
Input: Supply
Sensor 071.
Included
Input:
Unoccupied
signal.
Optional
Input:
tekmar 10K
Zone Control
Optional
Output: Turn on stages #1 to #8
Output: Open
Combustion Air
Damper
Input: Heat Demand
signal.
Optional
Output: Turn
on System
Pump
24Vac power supply
Stages 1 to 8
are on
Outdoor Reset Strategy . . . . . . pg. 2 Error Messages . . . . . . . . . pg. 14
Sequence of Operation . . . . . . pg. 4 Programming . . . . . . . . . . . pg. 15
Installation . . . . . . . . . . . . . . . . . pg. 7 Pre-Programed Schedules pg. 18
Settings . . . . . . . . . . . . . . . . . . . pg. 10 Technical Data . . . . . . . . . . pg. 19
Testing . . . . . . . . . . . . . . . . . . . . pg. 13 Limited Warranty . . . . . . . . pg. 20
The tekmar Eight Stage Boiler Control 258 is a microprocessor-based control which
regulates the supply water temperature from up to 8 boilers based on the outdoor air
temperature, and optionally, the indoor air temperature through a tekmar 10K Zone
Control. The System pump is turned on when there is a Heat Demand and the outdoor
temperature is cool enough to require heat in the system. When a combustion air
damper is used, it must be opened before the first boiler is fired. The control has a
built-in setback timer and LCD screen to display temperatures and boiler running times.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tekmar Eight Stage Boiler Control 258 and is the answer not in the manual?

Tekmar Eight Stage Boiler Control 258 Specifications

General IconGeneral
Stages8
ApplicationBoiler Control
CompatibilityCompatible with most boilers
DisplayLCD
MountingWall mount
Voltage24VAC
Control TypeStaged