Register your Sensor (with OTAA) and Gateway on the Network Server. (Follow the
Tektelic Network Server Guide T0005158_NS.)
4. Apply power to the Gateway using either DC power or POE:
a. For DC power, apply 48VDC power to the Kona Macro Gateway. Ensure that
current limit of power supply is set for 1A or greater. Current draw is
approximately 0.2A during initialization and 0.5A when initialization is complete.
If there is no current, the polarity of the DC power cable connection may be
reversed, or the power source may not be configured properly.
b. If using POE, the injector must support 56VDC output and can supply 0.8A or
greater of current.
5. Module Bootup:
Bootup time of the Gateway is approximately 2 minutes. During bootup, the LED status
is Flashing Green.
6. Module LED status:
After bootup, LED status will be Flashing RED. The LED will remain flashing red until the
Gateway receives a downlink packet from the Network Server. Upon reception of a
downlink packet from the Network Server, the LED will change to Solid Green. (Refer
table 1 for different LED states).
7. Retrieve Module IP address:
The Kona Macro Gateway supports DHCP on the Ethernet port. The Gateway MAC
address is printed on the Gateway label. Using the MAC address and your local DHCP
tools, determine the IP address of the Gateway.
8. Start KonaFT:
Launch KonaFT. Enter your gateway’s IP address and port number 161 (default) on
KonaFT then Select Start Button.