EasyManua.ls Logo

Tektronix 1910 - Sync and Subcarrier Specifications

Tektronix 1910
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table
SYNC & SUBCARRIER
Specification-1910
Operators
Performance
I
Supplemental
Perf. Ck.
Characteristics
Requirements
Information
Step.
No.
COMPOSITE SYNC
Amplitude
4V ±10%
P-P.
negative going, into
75
Q
Rise & Fall Times
140ns
±20ns
Measured from 10% to 90% ampli-
tude points.
Return Loss At least 30
dB
to
3.58
MHz
53
Line Period
Nominal
(H)
=
63.556/ls
1
Subcarrier X2
455
Line Sync Duration
4.7.us ± 50 ns Measured at
50%
amplitude point.
Equalizer Pulse
Duration
2.3,us ± 50 ns Measured at
50%
amplitude point.
Sequence Duration
Three lines each.
Vertical Sync Pulse
Serration 4.7
,us
± 50
ns
Sequence Duration
Three lines.
Field Period 262.5 H Lines
16.6835 ms nominal.
SUBCARRIER
Amplitude 2V
pop
±10%
Into 75
n.
Return Loss
At
least 30
dB
into 5
MHz
53
Frequency
Locked
to
incoming burst. 25
If burst is not present, locked to
leading edge
of
incoming sync.
If
I
sync
is
not present, determined by
an internal oven-controlled
oscillator.
1-33