Table
SYNC & SUBCARRIER
Specification-1910
Operators
Performance
I
Supplemental
Perf. Ck.
Characteristics
Requirements
Information
Step.
No.
COMPOSITE SYNC
Amplitude
4V ±10%
P-P.
negative going, into
75
Q
Rise & Fall Times
140ns
±20ns
Measured from 10% to 90% ampli-
tude points.
Return Loss At least 30
dB
to
3.58
MHz
53
Line Period
Nominal
(H)
=
63.556/ls
1
Subcarrier X2
455
Line Sync Duration
4.7.us ± 50 ns Measured at
50%
amplitude point.
Equalizer Pulse
Duration
2.3,us ± 50 ns Measured at
50%
amplitude point.
Sequence Duration
Three lines each.
Vertical Sync Pulse
Serration 4.7
,us
± 50
ns
Sequence Duration
Three lines.
Field Period 262.5 H Lines
16.6835 ms nominal.
SUBCARRIER
Amplitude 2V
pop
±10%
Into 75
n.
Return Loss
At
least 30
dB
into 5
MHz
53
Frequency
Locked
to
incoming burst. 25
If burst is not present, locked to
leading edge
of
incoming sync.
If
I
sync
is
not present, determined by
an internal oven-controlled
oscillator.
1-33