Type and
size
Function Type of user
info stored
Method of
modification
Data input
method
Location User
acce-
ssible
To clear To sanitize
Flash
Memory 32
KB
Stores power
management
micro-controller
firmware
None Indirectly Application
software
operations
Internal to
the
MC9S08
micro-
controller
on the
acquisition
board
No Not applicable, does
not contain user data
or settings. Clearing or
sanitizing would disable
instrument functionality.
FRAM 32 KB Stores host
processor power
sequencer micro-
controller
firmware
None Indirectly Application
software
operations
Internal to
the
MSP430
micro-
controller
on the
processor
board
No Not applicable, does
not contain user data
or settings. Clearing or
sanitizing would disable
instrument functionality.
Flash
Memory 64
KB
Stores analog
front end micro-
controller
firmware
None Indirectly Application
software
operations
Internal to
the KL14
micro-
controller
on the
Acquisition
board
No Not applicable, does
not contain user data
or settings. Clearing or
sanitizing would disable
instrument functionality.
Flash
Memory 256
KB
Stores front
panel micro-
controller
firmware
None Indirectly Application
software
operations
Internal to
the TIVA
TM4C
micro-
controller
on the front
panel LED
board
No Not applicable, does
not contain user data
or settings. Clearing or
sanitizing would disable
instrument functionality.
FPGA NOR
Flash 64 MB
Stores FPGA
configuration
None Indirectly Application
software
operations
Acquisition
board
No Not applicable, does
not contain user data
or settings. Clearing or
sanitizing would disable
instrument functionality.
FPGA NOR
Flash 64 MB
Stores backup
copy of FPGA
configuration
None Indirectly Application
software
operations
Acquisition
board
No Not applicable, does
not contain user data
or settings. Clearing or
sanitizing would disable
instrument functionality.
Clear and sanitize procedures
MSO44, MSO46, MSO44B, and MSO46B 4 Series Mixed Signal Oscilloscopes Declassification and Security Instructions 9

Other manuals for Tektronix 4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix 4 Series and is the answer not in the manual?

Tektronix 4 Series Specifications

General IconGeneral
BrandTektronix
Model4 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals