Commands Listed in Alphabetical Order
“V”;YMULT 4.00
00E-3;YOFF 0.0000;YZERO 0.0000;:CURVE
2,1,4,2,4,3,0,3,3,3,3,3,3, 4,3,5,6,6,7,3
WFMInpre? (Query Only)
Returns the waveform formatting and scaling specications to be applied to the
next incoming CURVe command data.
Group
Waveform Transfer
Syntax
WFMInpre?
Related Commands
WFMOutpre?
Examples
WFMINPRE? might return the waveform formatting as :WFMINPRE:BIT_N R
8;BN_FMT RI;BYT_NR 1; BYT_OR MSB;ENCDG B IN;NR_PT 500;PT_FMT
Y; PT_O FF 0;XINCR 2.0000E-6;XZERO 1.7536E-6; XUNIT "s";YMULT
1.0000E-3;YOFF 0.0000; YZERO 0.0000;YUNIT "V"
WFMInpre:BIT_Nr
Sets or returns the number of bits per binary waveform point for the incoming
waveform. Changing the value of WFMInpre:BIT_Nr also changes the value of
WFMInpre:BYT_Nr.
Group
Waveform Transfer
Syntax
WFMInpre:BIT_Nr <NR1>
WFMInpre:BIT_Nr?
Related Commands
WFMInpre:BYT_Nr
Arguments
<NR1> number of bits per data point can be 8 or 16.
Examples
WFMINPRE:BIT_NR 16 sets the number of bits per waveform point to 16, for
incoming data.
WFMINPRE:BIT_NR? might return :WFMIN PRE:BIT_NR 8 indicating that
incoming waveform data uses 8 bits per waveform point.
MSO2000B, DPO2000B, MSO2000 and DPO2000 Series Oscilloscopes Programmer Manual 2-353

Other manuals for Tektronix DPO2012B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DPO2012B and is the answer not in the manual?

Tektronix DPO2012B Specifications

General IconGeneral
BrandTektronix
ModelDPO2012B
CategoryTest Equipment
LanguageEnglish

Related product manuals