EasyManua.ls Logo

Tektronix MSO70404C

Tektronix MSO70404C
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
x
MSO70000C/DX Series Mixed Signal Oscilloscopes
DPO70000C/DX Series Digital Phosphor Oscilloscopes
DPO7000C Series Digital Phosphor Oscilloscopes
MSO5000B and DPO5000B Series Oscilloscopes
ZZZ
User Manual
*P071298004*
071-2980-04

Table of Contents

Other manuals for Tektronix MSO70404C

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO70404C and is the answer not in the manual?

Tektronix MSO70404C Specifications

General IconGeneral
Bandwidth4 GHz
Channels4
Sample Rate (Digital)10 GS/s
Operating SystemWindows
Probe InterfaceTekVPI
Display12.1 in. color TFT LCD
Vertical Resolution8 bits
Input Impedance50 Ω or 1 MΩ
Maximum Input Voltage (50 Ω)5 Vrms
Maximum Input Voltage (1 MΩ)400 V peak
Trigger TypesEdge, Pulse, Runt, Timeout, Window, Logic, Video

Summary

Important safety information

General safety summary

Review safety precautions to avoid injury and prevent damage.

To avoid fire or personal injury

Use proper power cord, ground product, disconnect power, connect/disconnect properly.

Service safety summary

Information for safely performing service procedures by qualified personnel.

Install your instrument

Preventing ESD

Explains how to prevent Electrostatic Discharge damage to the instrument.

Powering on the instrument

Lists power supply requirements and power consumption for different series.

Getting acquainted with your instrument

Acquisition

Signal path compensation

Procedure to perform signal path compensation for accurate measurements.

Setting up analog signal input

Steps to connect probes and select input channels for signal acquisition.

Pinpoint triggers

Triggering concepts

Explains trigger events, modes (Normal, Auto), and trigger holdoff.

Using a (Main) and b (Delayed) triggers

Using A Event trigger for simple signals and B Event for complex signals.

Display a waveform

Analyzing waveforms

Taking automatic measurements

How to select channels and choose measurements in five categories.

Using mask testing

How to compare signals to predefined templates or masks for testing.

Using limit testing

How to compare active signals with template waveforms for pass/fail testing.

MyScope

Saving and recalling information

Application examples

Capturing intermittent anomalies

Using FastAcq to find and capture intermittent anomalies in signals.

Triggering on buses

How to set up bus triggers for I2C, SPI, RS-232, USB, CAN, and parallel buses.

Related product manuals