CALIBRATION
TEST
EQUIPMENT
REPLACEMENT
Calibration
Test
Equipment
Chart
This
chart
compares
TM
500
product
performance
to that
of
older
Tektronix
equipment
.
Only
those
characteristics
where
significant
specification
differences
occur, are
listed
.
In
some
cases
the
new
instrument
may
not
bea
total
functional
replacement
.
Additional
support
instrumentation
may
be
needed
or
a change
in
calibration
procedure
may
be
necessary
.
NOTE
:
All
TM
500
generator
outputs are
short-proof
.
All
TM
500
plug-in
instruments
require
TM
500-Series
Power
Module
.
REV
.
A,
OCT
1975
Comparison
of
Main
Characteristics
-
Amplitude
range
40
mV
to
10
V
p-p
.
-
Frequency
range
350
kHz
to
100
MHz
.
-
Frequency
range
65
MHz
to
500
MHz
.
Marker
outputs,
5 sec
to
1
/is
.
Sinewave
available
at 20,
10,
and
2 ns
.
Trigger
pulses
1,
10,
100
Hz
;
1,
10,
and
100
kHz
.
Multiple
time-marks
can
be
generated
simultaneously
.
-
Marker
outputs,
1,
10,
100,
1000,
and
10,000
Ns,
plus
10
ns
sinewave
.
-
Marker
outputs,
5
sec
to
2
ns
.
Sine-
wave
available
at
50,
20, 10,
5,
and
2
ns
.
Separate
trigger
pulses
of
1
and
.1
sec
;
10,
1,
and
.1
ms
;
10
and
1
Ns
.
Marker
amplifier
pro-
vides positive
or
negative
time
marks
of
25
V
min
.
Marker
intervals
of
1
and
.1
sec
;
10,
1,
and
.1
ms
;
10
and
1
/is
.
-
Marker
outputs,
5
sec
to
0
.1
ps
.
Sinewave
available
to
50, 10,
and
5
ns
.
Separate
trigger
pulses,
from
5
sec
to
0
.1
ps
.
Multiple
time-marks
can
be
gene-
rated
simultaneously
.
190A,
190B
191
067-0532-01
SG
503
-
Amplitude range
5
mV
to
5
.5
V p-p
.
SG
503
-
Frequency
range
250
kHz
to
250
MHz
.
SG
503
-
Frequency
range
250
kHz
to
250
MHz
.
190B
191
0532-01
TG
501
replaces
180,
180A
TG
501
Marker
outputs,
5 sec
to
1
ns
.
180A
Sinewave
available
at 5,
2,
and
1
ns
.
Trigger
output
-
slaved
to
marker
output
from
5
sec
through
100
ns
.
One
time-mark
can
be
generated
at
a
time
.
181
TG
501
Marker
outputs,
5 sec
to
1
ns
.
Sine-
181
wave
available
at
5,
2,
and
1
ns
.
184
TG
501
Marker
outputs,
5 sec
to
1
ns
.
Sine-
18
wave
available
at
5,
2,
and
1
ns
.
Trigger
output
-
slaved
to
marker
output
from
5
sec
through
100
ns
.
One
time-mark
can
be
generated
at
a
time
.
2901
TG
501
Marker
outputs,
5 sec
to
1
ns
.
Sine-
2901
wave
available
at
5,
2,
and
1
ns
.
Trigger
output
-
slaved
to
marker
output
from
5 sec
through
100
ns
.
One
time-mark
can
be
generated
at
a
time
.
DM
501
replaces
7D13
PG
501
replaces
107
PG
501
-
Risetime
less
than 3
.5
ns
into
107-
Risetime
less
than 3
.0
ns
into
500
.
50
O
.
108
PG
501
-
5 V
output
pulse
;
3
.5
ns
Risetime
.
108-
10 V output
pulse
;
1
ns Risetime
.
111
PG
501
-
Risetime
less
than
3
.5
ns
;
8 ns
111
-
Risetime
0
.5
ns
;
30
to
250 ns
Pretrigger
pulse delay
.
Pretrigger Pulse delay
.
114
PG
501
-
±5
V output
.
114-
±10V
output
.
Short proof output
.
115
PG
501
-
Does
not
have
Paired,
Burst,
Gated,
115-
Paired,
Burst,
Gated,
and
Delayed
or
Delayed
pulse
mode
;
±5V
do
pulse
mode
;
±10V
output
.
Offset
.
Has
±5
V
output
.
Short-proof
output
.
PG
502
replaces
107
108
PG
502
-
5 V
output
108
-
10
V
output
.
111
PG
502
-
Risetime
less
than
1
ns
;
10
ns
111
-
Risetime 0
.5
ns
;
30
to
250
ns
Pretrigger
pulse
delay
.
Pretrigger
pulse delay
.
114
PG
502
-
±5
V output 114
-
±10V
output
.
Short
proof output
.
115
PG
502
-
Does
not
have
Paired,
Burst,
Gated, 115
-
Paired,
Burst,
Gated,
Delayed
&
Un-
Delayed
&
Undelayed
pulse
mode
;
delayed
pulse
mode
;
±10
V output
.
Has
±5V
output
.
Short-proof
output
.
2101
PG
502
-
Does
not
have
Paired
or
Delayed
2101
-
Paired
and
Delayed
pulse
;
10
V
pulse
.
Has
±5
V
output
.
output
.
PG
506
replaces
106
PG
506
-
Positive-going
trigger
output
signal
106
-
Positive
and
Negative-going
trigger
at
least
1
V
;
High
Amplitude
out-
output
signal,
50
ns
and
1
V
;
High
put,
60
V
.
Amplitude
output,
100 V
.
067-0502-01
PG
506
-
Does
not
have
chopped
feature
.
0502-01
-
Comparator
output
can
be
alter-
nately
chopped
to
a
reference
voltage
.
SG
503
replaces
190,