Compliance information
Compliance in
formation
This section
lists the EMC (electromagnetic compliance), safety, and
environmental standards with which the instrument complies. This product is
intended for use by professionals and trained personnel only; it is not designed
for use in households or by children.
Questions about the following compliance information may be directed to the
following address:
Tektronix, Inc.
PO Box 500, MS 19-045
Beaverton, OR 97077, USA
www.tek.com
EMC compliance (TCPA300/400 only)
EU EMC Directive
Meets intent of Directive 2014/30/EU for Electromagnetic Compatibility.
Compliance was demonstrated to the following specications as listed in the
Ofcial Journal of the European Communities:
EN 61326-1, EN 61326-2-1. EMC requirements for electrical equipment for
measurement, control, and laboratory use.
1234
CISPR 11. Radiated and conducted emissions, Group 1, Class A
IEC 61000-4-2. Electrostatic discharge immunity
IEC 61000-4-3. RF electromagnetic eld immunity
IEC 61000-4-4. Electrical fast transient/burst immunity
IEC 61000-4-5. Power line surge immunity
IEC 61000-4-6. Conducted RF immunity
IEC 61000-4-11. Voltage dips and interruptions immunity
EN 61000-3-2. AC power line h armonic emissions
EN 61000-3-3. Voltage changes, uctuations, and icker
1
This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic
interference.
2
Emissions which exceed the levels required by this standard may occur when this equipment is connected to a
test object.
3
Equipment may not meet the immunity req
uirements of applicable listed standards when test leads and/or t est
probes are connected due to coupling of electromagnetic interference onto those leads/probes. To minimize the
inuence of electromagnetic interference, minimize the loop area between the unshielded portions of signal and
associated return leads, and keep leads as far away as possible from electromagnetic disturbance sources.
Twisting unshielded test leads together is an effective way to reduce loop area. For probes, keep the ground
6Ampliers a nd Current Probes Compliance and Safety Instructions

Other manuals for Tektronix TCP303

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TCP303 and is the answer not in the manual?

Tektronix TCP303 Specifications

General IconGeneral
BrandTektronix
ModelTCP303
CategoryAmplifier
LanguageEnglish

Related product manuals