Command Descriptions
2–124
TDS Family Oscilloscope Programmer Manual
FULl specifies a frame, a grid, and cross hairs.
GRId specifies a frame and a grid.
NTSc specifies a special NTSC frame.
PAL specifies a special PAL frame.
DISPLAY:GRATICULE GRID
sets the graticule type to display a frame and a grid.
DISPLAY:GRATICULE?
returns FULL when all graticule elements (grid, frame, and cross hairs) are
selected.
DISplay:INStavu:PERSistence
TDS 500C & 700C Only
Selects the persistence mode to use with InstaVu.
Display
DISplay:INStavu:PERSistence { INFPersist | VARpersist }
DISplay:INStavu:PERSistence?
INStavu
:
<Space>
?
INFPersist
DISplay
VARpersist
PERSistence:
INFPersist accumulates data points on the display indefinitely.
VARpersist leaves acquired data points on the display for a period of time
specified by DISplay:INStavu:VARpersist.
DISPLAY:INSTAVU:PERSISTENCE?
might return INFPERSIST indicating the infinite persistence mode is on.
Examples
Group
Syntax
Arguments
Examples

Table of Contents

Other manuals for Tektronix TDS 500C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS 500C and is the answer not in the manual?

Tektronix TDS 500C Specifications

General IconGeneral
BrandTektronix
ModelTDS 500C
CategoryTest Equipment
LanguageEnglish

Related product manuals